Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 2001 |
Principal Product | Roofing Products |
NAICS | n/a |
SIC | 2231 - Broadwoven Fabric Mills, Wool |
Sales | $10,000,000-$50,000,000 |
# of Employees | 70 |
Plant Area (Sq.Ft.) | 300,000 |
Annual Production | 69,484 Tons |
Production Hrs. Annual | 6,240 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $177,052 | 2,569,451 | kWh | $0.07 |
Electricity Demand | $48,636 | 5,528 | kW-months/year | $8.80 |
Fuel Oil #2 | $301,704 | 274,276 | MMBtu | $1.10 |
TOTAL ENERGY COSTS | $532,627 | |||
RECOMMENDED SAVINGS* | $100,310 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $20,449 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Water Disposal | Administrative Changes | Electricity Usage | Electricity Demand | Water Disposal | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | Tgal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $5,548 Cost: $9,647 |
$4,358 | 56,599 | $1,190 | 11 | - | - | - | - |
$4,358 56,599 kWh |
$1,190 11 kW-months/year |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES |
Savings: $17,357 Cost: $50 |
- | - | - | - | - | - | $17,357 | - |
- - kWh |
- - kW-months/year |
- - Tgal |
$17,357 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7121 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT |
Savings: $20,280 Cost: $49,350 |
$14,646 | 190,208 | $6,124 | 58 | - | - | $(-490) | - |
$14,646 190,208 kWh |
$6,124 58 kW-months/year |
- - Tgal |
$(-490) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4238 DO NOT USE COMPRESSED AIR FOR PERSONAL COOLING |
Savings: $6,860 Cost: $1,212 |
$6,860 | 71,454 | - | - | - | - | - | - |
$6,860 71,454 kWh |
- - kW-months/year |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $6,066 Cost: $450 |
$5,266 | 69,406 | $800 | 9 | - | - | - | - |
$5,266 69,406 kWh |
$800 9 kW-months/year |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.4155 METER WASTE WATER |
Savings: $5,235 Cost: $1,500 |
- | - | - | - | $5,235 | - | - | - |
- - kWh |
- - kW-months/year |
$5,235 - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $645 Cost: $1,895 |
- | - | - | - | - | - | $645 | - |
- - kWh |
- - kW-months/year |
- - Tgal |
$645 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.5316 CONTRACT A WOOD PALLET RECYCLING COMPANY |
Savings: $1,485 Cost: - |
- | - | - | - | - | - | $1,485 | - |
- - kWh |
- - kW-months/year |
- - Tgal |
$1,485 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 4.448 INSTALL AUTOMATIC PART STORAGE / RETREVAL SYSTEM |
Savings: $29,484 Cost: $5,113 |
- | - | - | - | - | - | $29,484 | - |
- - kWh |
- - kW-months/year |
- - Tgal |
$29,484 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 4.431 TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY |
Savings: $7,350 Cost: $800 |
- | - | - | - | - | - | $7,350 | - |
- - kWh |
- - kW-months/year |
- - Tgal |
$7,350 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $100,310 Cost: $70,017 |
$31,130 | 387,667 | $8,114 | 78 | $5,235 | - | $55,831 | - | $31,130 387,667 kWh |
$8,114 78 kW-months/year |
$5,235 - Tgal |
$55,831 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $20,449 Cost: $10,897 |
$9,624 | 126,005 | $1,990 | 20 | - | - | $8,835 | - | $9,624 126,005 kWh |
$1,990 20 kW-months/year |
- - Tgal |
$8,835 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | Tgal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Water Disposal | Administrative Changes | Electricity Usage | Electricity Demand | Water Disposal | Administrative Changes |