IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

100

matching recommendations
Reset
SIC 221 Broadwoven Fabric Mills, Cotton
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
GT0767 # 08 Y:2003 08 2003 INCREASE AMOUNT OF CONDENSATE RETURNED $25,099 $11,100 Not Implemented
GT0767 # 06 Y:2003 06 2003 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $16,712 $6,500 Not Implemented
GT0767 # 05 Y:2003 05 2003 USE OPTIMUM TEMPERATURE $9,365 $5,650 Not Implemented
GT0767 # 04 Y:2003 04 2003 INSULATE BARE EQUIPMENT $2,317 $298 Not Implemented
GT0767 # 03 Y:2003 03 2003 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $15,699 $2,088 Implemented
GT0767 # 02 Y:2003 02 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,500 $1,250 Implemented
GT0767 # 01 Y:2003 01 2003 ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS $2,362 $100 Implemented
GT0766 # 07 Y:2003 07 2003 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $108,981 $44,500 Not Implemented
GT0766 # 02 Y:2003 02 2003 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $30,090 $6,864 Not Implemented
GT0766 # 01 Y:2003 01 2003 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $770 $500 Not Implemented
GT0766 # 04 Y:2003 04 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $11,159 $6,250 Implemented
GT0766 # 06 Y:2003 06 2003 INSULATE BARE EQUIPMENT $3,238 $386 Not Implemented
GT0766 # 05 Y:2003 05 2003 REPAIR AND ELIMINATE STEAM LEAKS $5,000 $1,000 Implemented
GT0766 # 09 Y:2003 09 2003 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $70,877 $80,650 Not Implemented
GT0766 # 08 Y:2003 08 2003 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,589 $49,906 Implemented
GT0766 # 03 Y:2003 03 2003 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $32,869 $500 Implemented
GT0705 # 06 Y:2000 06 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,784 $16,840 Not Implemented
GT0705 # 08 Y:2000 08 2000 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK $120,000 $700,000 Not Implemented
GT0705 # 07 Y:2000 07 2000 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $5,152 $44,647 Not Implemented
GT0705 # 01 Y:2000 01 2000 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $37,979 $10,000 Not Implemented
GT0705 # 05 Y:2000 05 2000 REUSE / RECYCLE/ SELL PAPER PRODUCTS $3,265 $0 Not Implemented
GT0705 # 02 Y:2000 02 2000 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) $6,635 $8,000 Not Implemented
GT0705 # 04 Y:2000 04 2000 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,420 $0 Implemented
GT0705 # 03 Y:2000 03 2000 MINIMIZE WATER USAGE $1,457 $300 Implemented
GT0573 # 03 Y:1995 03 1995 SUBSTITUTE COMPRESSED AIR COOLING WITH WATER OR AIR COOLING $1,950 $6,270 Implemented