Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

19

matching recommendations
Reset
SIC 221 Broadwoven Fabric Mills, Cotton
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UA3021 # 09 Y:2012 09 2012 USE OPTIMUM THICKNESS INSULATION $286 $886 Not Implemented
UA3021 # 08 Y:2012 08 2012 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $531 $1,400 Not Implemented
UA3021 # 07 Y:2012 07 2012 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,473 $4,600 Not Implemented
UA3021 # 06 Y:2012 06 2012 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,846 $8,295 Not Implemented
UA3021 # 05 Y:2012 05 2012 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $6,933 $480 Not Implemented
UA3021 # 04 Y:2012 04 2012 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $8,268 $960 Not Implemented
UA3021 # 03 Y:2012 03 2012 INSTALL OCCUPANCY SENSORS $11,129 $5,264 Not Implemented
UA3021 # 02 Y:2012 02 2012 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $18,324 $82,319 Not Implemented
UA3021 # 01 Y:2012 01 2012 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $26,818 $40,135 Not Implemented
GT0574 # 04 Y:1995 04 1995 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT $134,001 $144,000 Not Implemented
GT0574 # 03 Y:1995 03 1995 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $4,516 $200 Not Implemented
GT0574 # 02 Y:1995 02 1995 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,668 $2,683 Not Implemented
GT0574 # 01 Y:1995 01 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $12,205 $26,520 Not Implemented
GT0519 # 01 Y:1994 01 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,860 $14,260 Implemented
GT0519 # 06 Y:1994 06 1994 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $45,180 $180,000 Not Implemented
GT0519 # 05 Y:1994 05 1994 INCREASE AMOUNT OF CONDENSATE RETURNED $14,440 $6,500 Implemented
GT0519 # 04 Y:1994 04 1994 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $19,600 $30,000 Not Implemented
GT0519 # 03 Y:1994 03 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $5,215 $5,215 Not Implemented
GT0519 # 02 Y:1994 02 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,190 $35,300 Not Implemented