IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

16

matching recommendations
Reset
SIC 2241 Narrow Fabric Mills
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MA0670 # 01 Y:2011 01 2011 INSULATE BARE EQUIPMENT $11,262 $5,845 Implemented
MA0670 # 02 Y:2011 02 2011 OPTIMIZE PLANT POWER FACTOR $3,931 $7,260 Implemented
MA0670 # 03 Y:2011 03 2011 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,994 $1,800 Implemented
MA0670 # 04 Y:2011 04 2011 USE MINIMUM SAFE OVEN VENTILATION $2,775 $6,150 Not Implemented
MA0670 # 05 Y:2011 05 2011 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $523 $1,000 Not Implemented
MA0413 # 01 Y:1998 01 1998 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $36,342 $53,316 n/a
MA0413 # 02 Y:1998 02 1998 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $4,782 $800 n/a
MA0413 # 03 Y:1998 03 1998 MINIMIZE CONDENSER COOLING WATER TEMPERATURE $2,015 $2,000 n/a
MA0413 # 04 Y:1998 04 1998 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $572 $1,000 n/a
MA0036 # 01 Y:1985 01 1985 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,352 $550 Not Implemented
MA0036 # 02 Y:1985 02 1985 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $13,279 $476 Not Implemented
MA0036 # 03 Y:1985 03 1985 DISCONNECT BALLASTS $2,457 $1,250 Not Implemented
MA0036 # 04 Y:1985 04 1985 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $450 $1,200 Not Implemented
MA0036 # 05 Y:1985 05 1985 BURN WASTE PAPER FOR HEAT $9,651 $9,075 Not Implemented
MA0036 # 06 Y:1985 06 1985 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $2,006 $2,027 Not Implemented
MA0036 # 07 Y:1985 07 1985 USE DEMAND CONTROLLER OR LOAD SHEDDER $5,548 $15,000 Not Implemented