Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

237

matching recommendations
Reset
SIC 225 Knitting Mills
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0177 # 01 Y:1999 01 1999 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $434 $120 Implemented
NC0177 # 02 Y:1999 02 1999 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,366 $2,141 Implemented
NC0177 # 03 Y:1999 03 1999 TURN OFF EQUIPMENT WHEN NOT IN USE $8,265 $420 Not Implemented
NC0177 # 04 Y:1999 04 1999 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $450 $500 Implemented
NC0177 # 05 Y:1999 05 1999 RECOVER AND REUSE COOLING WATER $97,444 $35,500 Implemented
NC0173 # 01 Y:1999 01 1999 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $311 $500 Not Implemented
NC0173 # 02 Y:1999 02 1999 INSTALL OCCUPANCY SENSORS $2,143 $875 Not Implemented
NC0173 # 03 Y:1999 03 1999 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $7,486 $27,000 Not Implemented
NC0173 # 04 Y:1999 04 1999 ADJUST BURNERS FOR EFFICIENT OPERATION $1,211 $800 Not Implemented
NC0173 # 05 Y:1999 05 1999 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS $235 $0 Not Implemented
NC0173 # 06 Y:1999 06 1999 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $375 $500 Not Implemented
NC0173 # 07 Y:1999 07 1999 ADD ADDITIONAL PRODUCTION SHIFT $6,000 $1,000 Not Implemented
NC0136 # 01 Y:1998 01 1998 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $4,876 $100 Implemented
NC0136 # 02 Y:1998 02 1998 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,667 $600 Implemented
NC0136 # 03 Y:1998 03 1998 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $6,035 $1,630 Not Implemented
NC0136 # 04 Y:1998 04 1998 PREHEAT COMBUSTION AIR WITH WASTE HEAT $10,803 $24,103 Not Implemented
NC0136 # 05 Y:1998 05 1998 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $4,000 $1,000 Implemented
NC0136 # 06 Y:1998 06 1998 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $1,263 $5,200 Not Implemented
NC0136 # 07 Y:1998 07 1998 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $281 $200 Implemented
NC0136 # 08 Y:1998 08 1998 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS $19,000 $62,834 Not Implemented
NC0104 # 01 Y:1996 01 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,017 $2,816 Implemented
NC0104 # 02 Y:1996 02 1996 USE PHOTOCELL CONTROLS $1,117 $630 Implemented
NC0104 # 03 Y:1996 03 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $195 $840 Implemented
NC0104 # 04 Y:1996 04 1996 INSTALL / REPAIR INSULATION ON STEAM LINES $1,717 $2,017 Implemented
NC0104 # 05 Y:1996 05 1996 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $9,962 $30,000 Not Implemented