Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
90
matching recommendationsSIC | 2258 | Lace & Warp Knit Fabric Mills |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0559 # 02 Y:2024 | 02 | 2024 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $519 | $27 | n/a |
SU0559 # 10 Y:2024 | 10 | 2024 | ADJUST / MAINTAIN FORK LIFT TRUCKS FOR MOST EFFICIENT OPERATION | $12,034 | $165,150 | n/a |
SU0559 # 09 Y:2024 | 09 | 2024 | USE HEAT PUMP FOR SPACE CONDITIONING | $175,181 | $421,500 | n/a |
SU0559 # 06 Y:2024 | 06 | 2024 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $3,988 | $4,574 | n/a |
SU0559 # 08 Y:2024 | 08 | 2024 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $577 | $888 | n/a |
SU0559 # 05 Y:2024 | 05 | 2024 | INSTALL / REPAIR INSULATION ON STEAM LINES | $5,926 | $3,523 | n/a |
SU0559 # 03 Y:2024 | 03 | 2024 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $498 | $27 | n/a |
SU0559 # 01 Y:2024 | 01 | 2024 | PAY BILLS ON TIME TO AVOID LATE FEES | $1,057 | $0 | n/a |
SU0559 # 07 Y:2024 | 07 | 2024 | INSTALL OR UPGRADE INSULATION ON HVAC DISTRIBUTION SYSTEMS | $37,111 | $44,118 | n/a |
SU0559 # 04 Y:2024 | 04 | 2024 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $662 | $307 | n/a |
NC0300 # 02 Y:2004 | 02 | 2004 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $2,558 | $5,000 | Implemented |
NC0300 # 04 Y:2004 | 04 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,688 | $6,890 | Not Implemented |
NC0300 # 01 Y:2004 | 01 | 2004 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $1,985 | $1,000 | Not Implemented |
NC0300 # 03 Y:2004 | 03 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $9,308 | $100 | Implemented |
NC0300 # 05 Y:2004 | 05 | 2004 | INSTALL OCCUPANCY SENSORS | $1,402 | $4,751 | Implemented |
NC0285 # 04 Y:2004 | 04 | 2004 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $956 | $1,380 | Not Implemented |
NC0285 # 05 Y:2004 | 05 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $48,918 | $20,000 | Not Implemented |
NC0285 # 06 Y:2004 | 06 | 2004 | ADJUST BURNERS FOR EFFICIENT OPERATION | $9,991 | $1,000 | Not Implemented |
NC0285 # 02 Y:2004 | 02 | 2004 | RECOVER AND REUSE COOLING WATER | $7,258 | $8,763 | Not Implemented |
NC0285 # 03 Y:2004 | 03 | 2004 | RECOVER AND REUSE COOLING WATER | $29,869 | $5,075 | Not Implemented |
NC0285 # 01 Y:2004 | 01 | 2004 | RECOVER AND REUSE COOLING WATER | $84,488 | $67,500 | Not Implemented |
NC0285 # 08 Y:2004 | 08 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,454 | $500 | Not Implemented |
NC0285 # 07 Y:2004 | 07 | 2004 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $11,507 | $23,675 | Not Implemented |
MS0217 # 11 Y:2002 | 11 | 2002 | REPAIR AND ELIMINATE STEAM LEAKS | $82 | $60 | Not Implemented |
MS0217 # 04 Y:2002 | 04 | 2002 | INSTALL OCCUPANCY SENSORS | $5,071 | $799 | Not Implemented |