Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
15
matching recommendationsSIC | 227 | Carpets And Rugs |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0343 # 01 Y:2008 | 01 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,158 | $32,000 | Not Implemented |
UM0343 # 02 Y:2008 | 02 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $10,585 | $10,000 | Not Implemented |
UM0343 # 03 Y:2008 | 03 | 2008 | USE OPTIMUM THICKNESS INSULATION | $8,476 | $9,576 | Not Implemented |
UM0343 # 04 Y:2008 | 04 | 2008 | USE RADIANT HEATER FOR SPOT HEATING | $3,750 | $0 | Implemented |
UM0343 # 05 Y:2008 | 05 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,390 | $5,864 | Not Implemented |
UM0343 # 06 Y:2008 | 06 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,378 | $750 | Implemented |
GT0846 # 01 Y:2008 | 01 | 2008 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $61,777 | $40,000 | Implemented |
GT0846 # 02 Y:2008 | 02 | 2008 | USE MINIMUM STEAM OPERATING PRESSURE | $16,146 | $15,536 | Implemented |
GT0846 # 03 Y:2008 | 03 | 2008 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $830 | $1,094 | Not Implemented |
GT0846 # 04 Y:2008 | 04 | 2008 | USE STEAM CONDENSATE FOR HOT WATER SUPPLY (NON-POTABLE) | $17,989 | $26,900 | Not Implemented |
GT0846 # 05 Y:2008 | 05 | 2008 | HEAT WATER WITH EXHAUST HEAT | $551,313 | $130,000 | Not Implemented |
GT0846 # 06 Y:2008 | 06 | 2008 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $59,040 | $65,000 | Implemented |
GT0846 # 07 Y:2008 | 07 | 2008 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $155,720 | $30,000 | Implemented |
GT0846 # 08 Y:2008 | 08 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $24,504 | $70,103 | Implemented |
GT0846 # 09 Y:2008 | 09 | 2008 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $18,206 | $35,000 | Not Implemented |