Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

21

matching recommendations
Reset
SIC 2273 Carpets And Rugs
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
KS2431 # 05 Y:2024 05 2024 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $52,635 $494,620 n/a
KS2431 # 04 Y:2024 04 2024 INSTALL OCCUPANCY SENSORS $10,405 $31,750 n/a
KS2431 # 03 Y:2024 03 2024 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $46,895 $154,122 n/a
KS2431 # 02 Y:2024 02 2024 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,373 $5,480 n/a
KS2431 # 01 Y:2024 01 2024 USE SOLAR HEAT TO MAKE ELECTRICTY $37,021 $362,701 n/a
GT0796 # 03 Y:2004 03 2004 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $835 $0 Implemented
GT0796 # 08 Y:2004 08 2004 RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING $792 $1,910 Not Implemented
GT0796 # 07 Y:2004 07 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $8,051 $50,551 Implemented
GT0796 # 06 Y:2004 06 2004 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $5,639 $9,925 Not Implemented
GT0796 # 05 Y:2004 05 2004 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $8,427 $1,750 Not Implemented
GT0796 # 04 Y:2004 04 2004 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $815 $500 Not Implemented
GT0796 # 02 Y:2004 02 2004 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $895 $200 Implemented
GT0796 # 01 Y:2004 01 2004 COMBINE UTILITY METERS $4,508 $9,000 Not Implemented
GT0287 # 01 Y:1986 01 1986 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $426 $608 Implemented
GT0287 # 08 Y:1986 08 1986 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $9,456 $35,000 Implemented
GT0287 # 07 Y:1986 07 1986 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $34,648 $0 Not Implemented
GT0287 # 06 Y:1986 06 1986 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $14,400 $10,000 Implemented
GT0287 # 05 Y:1986 05 1986 ESTABLISH EQUIPMENT MAINTENANCE SCHEDULE $2,720 $500 Implemented
GT0287 # 04 Y:1986 04 1986 MODIFY TEXTILE DRYERS $7,960 $1,000 Not Implemented
GT0287 # 03 Y:1986 03 1986 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $16,719 $1,000 Implemented
GT0287 # 02 Y:1986 02 1986 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,279 $5,745 Implemented