Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
642
matching recommendationsSIC | 228 | Yarn And Thread Mills |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AT0002 # 01 Y:1985 | 01 | 1985 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,115 | $5,740 | Implemented |
AT0002 # 02 Y:1985 | 02 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $299 | $300 | Not Implemented |
AT0002 # 03 Y:1985 | 03 | 1985 | INSTALL / REPAIR INSULATION ON STEAM LINES | $754 | $2,165 | Implemented |
AT0002 # 04 Y:1985 | 04 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,923 | $8,325 | Implemented |
GT0228 # 01 Y:1984 | 01 | 1984 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $2,400 | $5,000 | Not Implemented |
GT0228 # 02 Y:1984 | 02 | 1984 | INCREASE AMOUNT OF CONDENSATE RETURNED | $3,900 | $6,000 | Not Implemented |
GT0228 # 03 Y:1984 | 03 | 1984 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,500 | $1,654 | Implemented |
GT0228 # 04 Y:1984 | 04 | 1984 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $2,292 | $2,600 | Not Implemented |
GT0228 # 05 Y:1984 | 05 | 1984 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $637 | $500 | Implemented |
GT0228 # 06 Y:1984 | 06 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,814 | $2,100 | Implemented |
GT0228 # 07 Y:1984 | 07 | 1984 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $3,600 | $3,000 | Implemented |
GT0233 # 01 Y:1984 | 01 | 1984 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $9,800 | $8,000 | Not Implemented |
GT0233 # 02 Y:1984 | 02 | 1984 | REPAIR AND ELIMINATE STEAM LEAKS | $1,000 | $100 | Implemented |
GT0233 # 03 Y:1984 | 03 | 1984 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $11,800 | $17,000 | Not Implemented |
GT0233 # 04 Y:1984 | 04 | 1984 | CONTROL PRESSURE ON STEAMER OPERATIONS | $54,023 | $16,000 | Implemented |
GT0233 # 05 Y:1984 | 05 | 1984 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $11,500 | $8,000 | Implemented |
GT0233 # 06 Y:1984 | 06 | 1984 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $840 | $1,000 | Not Implemented |
GT0221 # 01 Y:1984 | 01 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $6,817 | $500 | Implemented |
GT0221 # 02 Y:1984 | 02 | 1984 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $4,716 | $5,000 | Not Implemented |
GT0221 # 03 Y:1984 | 03 | 1984 | INCREASE AMOUNT OF CONDENSATE RETURNED | $18,719 | $15,000 | Not Implemented |
GT0221 # 04 Y:1984 | 04 | 1984 | INCREASE AMOUNT OF CONDENSATE RETURNED | $2,089 | $2,000 | Not Implemented |
GT0221 # 05 Y:1984 | 05 | 1984 | ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF | $11,160 | $10,000 | Implemented |
GT0221 # 06 Y:1984 | 06 | 1984 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $23,900 | $12,000 | Not Implemented |
GT0221 # 07 Y:1984 | 07 | 1984 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,879 | $7,166 | Not Implemented |
GT0221 # 08 Y:1984 | 08 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,700 | $3,780 | Implemented |