Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
25
matching recommendationsSIC | 2295 | Coated Fabrics, Not Rubberized |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0204 # 12 Y:1997 | 12 | 1997 | CLEAR AND RENT EXISTING SPACE | $9,169 | $19,200 | Not Implemented |
AS0204 # 11 Y:1997 | 11 | 1997 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $56,857 | $66,040 | Not Implemented |
AS0204 # 10 Y:1997 | 10 | 1997 | USE EVAPORATION TO CONCENTRATE MATERIAL | $36,527 | $13,260 | Not Implemented |
AS0204 # 09 Y:1997 | 09 | 1997 | INSTALL TIMERS AND/OR THERMOSTATS | $324 | $320 | Not Implemented |
AS0204 # 08 Y:1997 | 08 | 1997 | INSTALL OCCUPANCY SENSORS | $696 | $1,650 | Not Implemented |
AS0204 # 07 Y:1997 | 07 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,188 | $1,381 | Not Implemented |
AS0204 # 06 Y:1997 | 06 | 1997 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,288 | $3,115 | Not Implemented |
AS0204 # 05 Y:1997 | 05 | 1997 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,579 | $0 | Not Implemented |
AS0204 # 04 Y:1997 | 04 | 1997 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,786 | $60 | Not Implemented |
AS0204 # 03 Y:1997 | 03 | 1997 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $6,113 | $8,000 | Not Implemented |
AS0204 # 02 Y:1997 | 02 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,248 | $16,974 | Not Implemented |
AS0204 # 01 Y:1997 | 01 | 1997 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $63,320 | $2,400 | Not Implemented |
AS0168 # 13 Y:1996 | 13 | 1996 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,455 | $1,200 | Implemented |
AS0168 # 01 Y:1996 | 01 | 1996 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $490 | $150 | Implemented |
AS0168 # 12 Y:1996 | 12 | 1996 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,967 | $8,690 | Implemented |
AS0168 # 11 Y:1996 | 11 | 1996 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,557 | $11,870 | Implemented |
AS0168 # 10 Y:1996 | 10 | 1996 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $228 | $0 | Implemented |
AS0168 # 09 Y:1996 | 09 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,991 | $7,201 | Implemented |
AS0168 # 08 Y:1996 | 08 | 1996 | REDUCE HEAT GAIN BY WINDOW TINTING | $2,966 | $10,750 | Not Implemented |
AS0168 # 07 Y:1996 | 07 | 1996 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $4,044 | $20,000 | Not Implemented |
AS0168 # 06 Y:1996 | 06 | 1996 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $11,824 | $0 | Implemented |
AS0168 # 05 Y:1996 | 05 | 1996 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $38,756 | $1,750 | Implemented |
AS0168 # 04 Y:1996 | 04 | 1996 | INSTALL OCCUPANCY SENSORS | $306 | $300 | Not Implemented |
AS0168 # 03 Y:1996 | 03 | 1996 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,596 | $0 | Implemented |
AS0168 # 02 Y:1996 | 02 | 1996 | USE SYNTHETIC LUBRICANT | $468 | $124 | Implemented |