IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

355

matching recommendations
Reset
SIC 2299 Textile Goods, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WI0067 # 04 Y:1989 04 1989 INSTALL TIMERS AND/OR THERMOSTATS $2,536 $750 Implemented
WI0067 # 05 Y:1989 05 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,120 $1,270 Implemented
WI0067 # 06 Y:1989 06 1989 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,671 $500 Implemented
WI0067 # 07 Y:1989 07 1989 TURN OFF EQUIPMENT WHEN NOT IN USE $1,540 $800 Not Implemented
WI0067 # 08 Y:1989 08 1989 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $825 $3,000 Not Implemented
WI0067 # 09 Y:1989 09 1989 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $686 $1,000 Not Implemented
WI0067 # 12 Y:1989 12 1989 INSTALL STORM WINDOWS AND DOORS $432 $1,488 Implemented
WI0067 # 11 Y:1989 11 1989 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $1,500 $1,500 Not Implemented
WI0067 # 10 Y:1989 10 1989 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $640 $0 Implemented
MA0117 # 02 Y:1988 02 1988 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $625 $105 Implemented
MA0117 # 03 Y:1988 03 1988 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $2,384 $5,878 Not Implemented
MA0117 # 04 Y:1988 04 1988 INSTALL TIMERS AND/OR THERMOSTATS $240 $75 Implemented
MA0117 # 05 Y:1988 05 1988 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $340 $0 Implemented
MA0117 # 06 Y:1988 06 1988 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $11,656 $2,040 Not Implemented
GT0312 # 01 Y:1987 01 1987 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $546 $0 Implemented
GT0312 # 02 Y:1987 02 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $100 $293 Implemented
GT0312 # 03 Y:1987 03 1987 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,184 $3,615 Implemented
GT0312 # 04 Y:1987 04 1987 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $185 $1,050 Not Implemented
GT0315 # 01 Y:1987 01 1987 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $230 $200 Not Implemented
GT0315 # 02 Y:1987 02 1987 USE DIRECT AIR SUPPLY TO EXHAUST HOODS $9,270 $13,000 Implemented
GT0315 # 03 Y:1987 03 1987 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $481 $0 Implemented
GT0315 # 04 Y:1987 04 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,340 $5,150 Implemented
GT0315 # 05 Y:1987 05 1987 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,018 $3,783 Not Implemented
MA0068 # 01 Y:1986 01 1986 USE DIRECT AIR SUPPLY TO EXHAUST HOODS $10,397 $4,021 Not Implemented
MA0068 # 02 Y:1986 02 1986 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $16,205 $165 Not Implemented