Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Wisconsin, Milwaukee
Assessment Year 1989
Principal Product TEXTILE FLOCK
NAICS n/a
SIC 2299 - Textile Goods, Nec
Sales $5,000,000-$10,000,000
# of Employees 80
Plant Area (Sq.Ft.) 0
Annual Production 1,250,000 Pounds
Production Hrs. Annual 6,000
Location (State) IL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $52,878 719,519 kWh $0.07
Natural Gas $88,805 27,621 MMBtu $3.22
TOTAL ENERGY COSTS $141,683
RECOMMENDED SAVINGS* $24,278 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $11,499
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.8113 PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER Savings:
$4,188
Cost:
-
- - $4,188 - -
-
kWh
$4,188
-
MMBtu
02: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS Savings:
$5,100
Cost:
-
$5,100 - - - $5,100
-
kWh
-
-
MMBtu
03: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$4,040
Cost:
$5,000
- - $4,040 1,255 -
-
kWh
$4,040
1,255
MMBtu
04: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$2,536
Cost:
$750
- - $2,536 788 -
-
kWh
$2,536
788
MMBtu
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,120
Cost:
$1,270
$1,120 15,240 - - $1,120
15,240
kWh
-
-
MMBtu
06: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$1,671
Cost:
$500
- - $1,671 519 -
-
kWh
$1,671
519
MMBtu
07: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$1,540
Cost:
$800
- - $1,540 478 -
-
kWh
$1,540
478
MMBtu
08: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$825
Cost:
$3,000
$825 11,137 - - $825
11,137
kWh
-
-
MMBtu
09: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT Savings:
$686
Cost:
$1,000
$844 11,430 $(-158) (-49) $844
11,430
kWh
$(-158)
(-49)
MMBtu
10: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$640
Cost:
-
$640 8,792 - - $640
8,792
kWh
-
-
MMBtu
11: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS Savings:
$1,500
Cost:
$1,500
- - $1,500 493 -
-
kWh
$1,500
493
MMBtu
12: 2.7494 INSTALL STORM WINDOWS AND DOORS Savings:
$432
Cost:
$1,488
- - $432 134 -
-
kWh
$432
134
MMBtu
TOTAL RECOMMENDED Savings:
$24,278
Cost:
$15,308
$8,529 46,599 $15,749 3,618 $8,529
46,599
kWh
$15,749
3,618
MMBtu
TOTAL IMPLEMENTED Savings:
$11,499
Cost:
$4,008
$6,860 24,032 $4,639 1,441 $6,860
24,032
kWh
$4,639
1,441
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas