Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
355
matching recommendationsSIC | 2299 | Textile Goods, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0068 # 03 Y:1986 | 03 | 1986 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $1,226 | $100 | Implemented |
MA0068 # 04 Y:1986 | 04 | 1986 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $8,103 | $20,000 | Not Implemented |
MA0068 # 05 Y:1986 | 05 | 1986 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $9,940 | $50 | Implemented |
MA0068 # 06 Y:1986 | 06 | 1986 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $3,079 | $1,500 | Not Implemented |
MA0064 # 01 Y:1986 | 01 | 1986 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $1,039 | $750 | Not Implemented |
MA0064 # 02 Y:1986 | 02 | 1986 | INSULATE BARE EQUIPMENT | $2,040 | $2,900 | Implemented |
MA0064 # 03 Y:1986 | 03 | 1986 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $17,162 | $8,300 | Implemented |
MA0064 # 04 Y:1986 | 04 | 1986 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $900 | $2,090 | Implemented |
MA0064 # 05 Y:1986 | 05 | 1986 | REPAIR OR REPLACE STEAM TRAPS | $26,958 | $10,450 | Implemented |
MA0064 # 06 Y:1986 | 06 | 1986 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $12,086 | $31,425 | Implemented |
LT0041 # 01 Y:1985 | 01 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $350 | $100 | Implemented |
LT0041 # 02 Y:1985 | 02 | 1985 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,397 | $1,000 | Not Implemented |
LT0041 # 03 Y:1985 | 03 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $1,008 | $450 | Implemented |
LT0041 # 04 Y:1985 | 04 | 1985 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $4,080 | $264 | Implemented |
LT0041 # 05 Y:1985 | 05 | 1985 | ELIMINATE COOLING OF PROCESS STREAMS WHICH SUBSEQUENTLY MUST BE HEATED AND VICE VERSA | $1,419 | $2,500 | Not Implemented |
LT0041 # 06 Y:1985 | 06 | 1985 | PLANT TREES OR SHRUBS NEAR WINDOWS TO SHIELD FROM SUNLIGHT | $400 | $990 | Implemented |
LT0041 # 07 Y:1985 | 07 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,040 | $859 | Implemented |
LT0041 # 08 Y:1985 | 08 | 1985 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $650 | $42 | Implemented |
UD0159 # 01 Y:1985 | 01 | 1985 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $812 | $0 | Implemented |
UD0159 # 02 Y:1985 | 02 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $219 | $580 | Implemented |
UD0159 # 03 Y:1985 | 03 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,687 | $218 | Implemented |
UD0159 # 04 Y:1985 | 04 | 1985 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,961 | $0 | Implemented |
UD0159 # 05 Y:1985 | 05 | 1985 | RECOVER WASTE HEAT FROM EQUIPMENT | $345 | $920 | Implemented |
GT0231 # 01 Y:1984 | 01 | 1984 | CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS | $35,206 | $60,000 | Implemented |
GT0231 # 02 Y:1984 | 02 | 1984 | REDESIGN PROCESS | $32,333 | $20,000 | Not Implemented |