Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,394

matching recommendations
Reset
SIC 23 Apparel And Other Textile Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
GT0305 # 05 Y:1986 05 1986 ADJUST VENTS TO MINIMIZE ENERGY USE $3,652 $1,000 Not Implemented
GT0305 # 06 Y:1986 06 1986 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,580 $0 Implemented
GT0305 # 07 Y:1986 07 1986 REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF $24,800 $49,200 Not Implemented
GT0305 # 08 Y:1986 08 1986 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $4,400 $1,000 Implemented
AT0055 # 01 Y:1986 01 1986 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $632 $403 Implemented
AT0055 # 02 Y:1986 02 1986 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $2,545 $4,500 Not Implemented
AT0055 # 03 Y:1986 03 1986 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,580 $0 Not Implemented
AT0055 # 04 Y:1986 04 1986 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,037 $500 Not Implemented
AT0055 # 05 Y:1986 05 1986 IMPROVE LUBRICATION PRACTICES $1,142 $0 Implemented
AT0055 # 06 Y:1986 06 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $287 $450 Implemented
AT0055 # 07 Y:1986 07 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $359 $474 Implemented
TN0294 # 01 Y:1986 01 1986 INSTALL TIMERS AND/OR THERMOSTATS $10,135 $2,675 Implemented
TN0294 # 02 Y:1986 02 1986 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,406 $195 Implemented
TN0294 # 03 Y:1986 03 1986 INSTALL / REPAIR INSULATION ON STEAM LINES $797 $941 Implemented
TN0294 # 04 Y:1986 04 1986 INSTALL SET-BACK TIMERS $1,320 $0 Implemented
TN0294 # 05 Y:1986 05 1986 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $201 $600 Not Implemented
TN0294 # 06 Y:1986 06 1986 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $567 $0 Implemented
TN0294 # 07 Y:1986 07 1986 INSULATE BARE EQUIPMENT $386 $152 Not Implemented
TN0290 # 01 Y:1986 01 1986 SEPARATE CONTROLS OF AIR HANDLERS FROM AC/ HEATING SYSTEMS $8,544 $9,080 Implemented
TN0290 # 02 Y:1986 02 1986 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $1,673 $3,100 Implemented
TN0290 # 03 Y:1986 03 1986 RECOVER WASTE HEAT FROM EQUIPMENT $948 $1,885 Not Implemented
TN0290 # 04 Y:1986 04 1986 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $3,162 $0 Not Implemented
TN0290 # 05 Y:1986 05 1986 INSTALL TURBULATORS $469 $500 Implemented
TN0290 # 06 Y:1986 06 1986 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $90 $50 Not Implemented
TN0290 # 07 Y:1986 07 1986 MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION $293 $500 Implemented