Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
772
matching recommendationsSIC | 232 | Men's And Boys' Furnishings, Work Clothing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0264 # 06 Y:2003 | 06 | 2003 | INSULATE BARE EQUIPMENT | $152 | $627 | Implemented |
NC0264 # 07 Y:2003 | 07 | 2003 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $1,875 | $500 | Not Implemented |
NC0264 # 08 Y:2003 | 08 | 2003 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $160 | $280 | Not Implemented |
NC0264 # 09 Y:2003 | 09 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $264 | $100 | Not Implemented |
NC0264 # 10 Y:2003 | 10 | 2003 | INSTALL TIMERS AND/OR THERMOSTATS | $1,393 | $350 | Implemented |
AS0361 # 01 Y:2003 | 01 | 2003 | INSTALL / REPAIR INSULATION ON STEAM LINES | $168 | $350 | Implemented |
AS0361 # 02 Y:2003 | 02 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,025 | $30 | Implemented |
AS0361 # 03 Y:2003 | 03 | 2003 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $1,305 | $1,400 | Not Implemented |
AS0361 # 04 Y:2003 | 04 | 2003 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $11,899 | $17,550 | Not Implemented |
AS0361 # 05 Y:2003 | 05 | 2003 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $2,290 | $482 | Implemented |
AS0361 # 06 Y:2003 | 06 | 2003 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $2,846 | $1,000 | Not Implemented |
LL0163 # 01 Y:2003 | 01 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,982 | $2,560 | Not Implemented |
LL0163 # 02 Y:2003 | 02 | 2003 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,665 | $690 | Not Implemented |
LL0163 # 03 Y:2003 | 03 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $479 | $20 | Not Implemented |
LL0163 # 04 Y:2003 | 04 | 2003 | INSTALL OCCUPANCY SENSORS | $182 | $104 | Not Implemented |
LL0163 # 05 Y:2003 | 05 | 2003 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $4,950 | $0 | Not Implemented |
UU0036 # 01 Y:2002 | 01 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,377 | $10,838 | Not Implemented |
UU0036 # 02 Y:2002 | 02 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $148 | $20 | Implemented |
UU0036 # 03 Y:2002 | 03 | 2002 | USE SYNTHETIC LUBRICANT | $75 | $44 | Implemented |
UU0036 # 04 Y:2002 | 04 | 2002 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $1,776 | $0 | Not Implemented |
MI0021 # 01 Y:2001 | 01 | 2001 | METER WASTE WATER | $13,904 | $3,650 | Not Implemented |
MI0021 # 02 Y:2001 | 02 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,770 | $312 | Implemented |
MI0021 # 03 Y:2001 | 03 | 2001 | MODIFY STARTUP/SHUTDOWN TIMES | $3,634 | $113 | Not Implemented |
MI0021 # 04 Y:2001 | 04 | 2001 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $2,275 | $7 | Not Implemented |
MI0021 # 05 Y:2001 | 05 | 2001 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $3,250 | $4,200 | Implemented |