IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

188

matching recommendations
Reset
SIC 2326 Men's and Boys' Work Clothing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
GT0372 # 03 Y:1989 03 1989 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $47 $0 Implemented
GT0372 # 04 Y:1989 04 1989 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $38 $46 Implemented
GT0372 # 05 Y:1989 05 1989 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $438 $0 Not Implemented
TN0290 # 01 Y:1986 01 1986 SEPARATE CONTROLS OF AIR HANDLERS FROM AC/ HEATING SYSTEMS $8,544 $9,080 Implemented
TN0290 # 02 Y:1986 02 1986 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $1,673 $3,100 Implemented
TN0290 # 03 Y:1986 03 1986 RECOVER WASTE HEAT FROM EQUIPMENT $948 $1,885 Not Implemented
TN0290 # 04 Y:1986 04 1986 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $3,162 $0 Not Implemented
TN0290 # 05 Y:1986 05 1986 INSTALL TURBULATORS $469 $500 Implemented
TN0290 # 06 Y:1986 06 1986 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $90 $50 Not Implemented
TN0290 # 07 Y:1986 07 1986 MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION $293 $500 Implemented
UD0126 # 01 Y:1984 01 1984 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $2,095 $1,000 Implemented
UD0126 # 02 Y:1984 02 1984 DISCONNECT BALLASTS $1,386 $2,310 Implemented
UD0126 # 03 Y:1984 03 1984 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $1,630 $0 Implemented