Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

150

matching recommendations
Reset
SIC 2329 Men's and Boys' Clothing, Not Elsewhere Classified
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LL0163 # 01 Y:2003 01 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,982 $2,560 Not Implemented
LL0163 # 02 Y:2003 02 2003 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,665 $690 Not Implemented
LL0163 # 03 Y:2003 03 2003 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $479 $20 Not Implemented
LL0163 # 05 Y:2003 05 2003 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $4,950 $0 Not Implemented
LL0163 # 04 Y:2003 04 2003 INSTALL OCCUPANCY SENSORS $182 $104 Not Implemented
UU0036 # 02 Y:2002 02 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $148 $20 Implemented
UU0036 # 01 Y:2002 01 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,377 $10,838 Not Implemented
UU0036 # 04 Y:2002 04 2002 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $1,776 $0 Not Implemented
UU0036 # 03 Y:2002 03 2002 USE SYNTHETIC LUBRICANT $75 $44 Implemented
MS0180 # 01 Y:2001 01 2001 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $1,502 $50 Implemented
MS0180 # 06 Y:2001 06 2001 USE DIRECT AIR SUPPLY TO EXHAUST HOODS $2,093 $1,573 Not Implemented
MS0180 # 07 Y:2001 07 2001 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $63 $48 Implemented
MS0180 # 03 Y:2001 03 2001 INSULATE BARE EQUIPMENT $211 $24 Not Implemented
MS0180 # 02 Y:2001 02 2001 INSTALL TIMERS AND/OR THERMOSTATS $2,283 $1,063 Not Implemented
MS0180 # 04 Y:2001 04 2001 INSULATE BARE EQUIPMENT $162 $83 Implemented
MS0180 # 05 Y:2001 05 2001 INSTALL / REPAIR INSULATION ON STEAM LINES $70 $88 Implemented
AS0267 # 02 Y:2000 02 2000 INSTALL OCCUPANCY SENSORS $2,547 $2,475 n/a
AS0267 # 03 Y:2000 03 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,204 $1,012 n/a
AS0267 # 04 Y:2000 04 2000 INSTALL SKYLIGHTS $2,171 $1,680 n/a
AS0267 # 05 Y:2000 05 2000 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $29,540 $31,800 n/a
AS0267 # 06 Y:2000 06 2000 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL $2,700 $60 n/a
AS0267 # 07 Y:2000 07 2000 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL $1,608 $60 n/a
AS0267 # 08 Y:2000 08 2000 CONDENSE OPERATION INTO ONE BUILDING $604,757 $2,250,000 n/a
AS0267 # 09 Y:2000 09 2000 PURCHASE EQUIPMENT INSTEAD OF LEASING $3,906 $12,060 n/a
AS0267 # 01 Y:2000 01 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $13,649 $30,357 n/a