Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
86
matching recommendationsSIC | 234 | Women's, Misses', Children's, And Infants' |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UU0089 # 04 Y:2005 | 04 | 2005 | AIR CONDITION ONLY SPACE NECESSARY | $33,020 | $2,085 | Not Implemented |
UU0089 # 01 Y:2005 | 01 | 2005 | OPTIMIZE PLANT POWER FACTOR | $1,110 | $4,290 | Implemented |
UU0089 # 05 Y:2005 | 05 | 2005 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $10,700 | $2,000 | Implemented |
UU0089 # 02 Y:2005 | 02 | 2005 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $1,820 | $1,500 | Not Implemented |
UU0089 # 03 Y:2005 | 03 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $17,940 | $21,000 | Not Implemented |
UU0090 # 04 Y:2005 | 04 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,040 | $500 | Not Implemented |
UU0090 # 03 Y:2005 | 03 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,540 | $5,920 | Not Implemented |
UU0090 # 02 Y:2005 | 02 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,520 | $4,570 | Not Implemented |
UU0090 # 01 Y:2005 | 01 | 2005 | AIR CONDITION ONLY SPACE NECESSARY | $11,500 | $225 | Implemented |
SF0158 # 03 Y:1999 | 03 | 1999 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $1,087 | $4,159 | Not Implemented |
SF0158 # 02 Y:1999 | 02 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,055 | $15,240 | Not Implemented |
SF0158 # 01 Y:1999 | 01 | 1999 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $896 | $1,474 | Not Implemented |
SF0158 # 04 Y:1999 | 04 | 1999 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $7,327 | $125 | Not Implemented |
BD0062 # 01 Y:1996 | 01 | 1996 | INSTALL OCCUPANCY SENSORS | $2,266 | $2,400 | Not Implemented |
BD0062 # 02 Y:1996 | 02 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,507 | $2,846 | Not Implemented |
BD0062 # 03 Y:1996 | 03 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $552 | $600 | Not Implemented |
BD0062 # 04 Y:1996 | 04 | 1996 | INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE | $509 | $80 | Not Implemented |
BD0062 # 05 Y:1996 | 05 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $299 | $388 | Not Implemented |
BD0062 # 06 Y:1996 | 06 | 1996 | RECOVER WASTE HEAT FROM EQUIPMENT | $336 | $500 | Not Implemented |
BD0062 # 07 Y:1996 | 07 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $229 | $450 | Not Implemented |
BD0062 # 08 Y:1996 | 08 | 1996 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $7,821 | $7,500 | Not Implemented |
BD0062 # 09 Y:1996 | 09 | 1996 | MINIMIZE WATER USAGE | $1,016 | $2,275 | Not Implemented |
BD0062 # 10 Y:1996 | 10 | 1996 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $881 | $2,245 | Not Implemented |
OD0043 # 02 Y:1995 | 02 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,495 | $1,756 | Not Implemented |
OD0043 # 01 Y:1995 | 01 | 1995 | INSTALL TIMERS AND/OR THERMOSTATS | $4,482 | $1,755 | Not Implemented |