Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
70
matching recommendationsSIC | 235 | Hats, Caps, And Millinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MO0059 # 10 Y:1992 | 10 | 1992 | INSTALL TIMERS AND/OR THERMOSTATS | $7,318 | $2,638 | Not Implemented |
MO0059 # 09 Y:1992 | 09 | 1992 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $335 | $0 | Not Implemented |
MO0059 # 08 Y:1992 | 08 | 1992 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $91 | $573 | Not Implemented |
MO0059 # 07 Y:1992 | 07 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,316 | $630 | Implemented |
MO0059 # 06 Y:1992 | 06 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,670 | $10,000 | Implemented |
MO0059 # 05 Y:1992 | 05 | 1992 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $536 | $96 | Implemented |
MO0059 # 04 Y:1992 | 04 | 1992 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,167 | $395 | Implemented |
MO0059 # 03 Y:1992 | 03 | 1992 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,545 | $20 | Not Implemented |
MO0059 # 02 Y:1992 | 02 | 1992 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $295 | $500 | Implemented |
MO0050 # 02 Y:1992 | 02 | 1992 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $959 | $1,700 | Implemented |
MO0050 # 01 Y:1992 | 01 | 1992 | ISOLATE HOT OR COLD EQUIPMENT | $8,525 | $1,400 | Implemented |
MO0050 # 03 Y:1992 | 03 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,886 | $0 | Not Implemented |
MO0050 # 04 Y:1992 | 04 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $885 | $7,000 | Implemented |
MO0050 # 05 Y:1992 | 05 | 1992 | INSULATE BARE EQUIPMENT | $3,204 | $8,800 | Implemented |
MO0050 # 06 Y:1992 | 06 | 1992 | INSULATE BARE EQUIPMENT | $3,153 | $1,113 | Not Implemented |
MO0050 # 07 Y:1992 | 07 | 1992 | INSULATE BARE EQUIPMENT | $898 | $820 | Not Implemented |
MO0050 # 08 Y:1992 | 08 | 1992 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,591 | $20 | Implemented |
MO0050 # 09 Y:1992 | 09 | 1992 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,526 | $200 | Not Implemented |
MO0050 # 10 Y:1992 | 10 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $238 | $957 | Not Implemented |
MO0050 # 11 Y:1992 | 11 | 1992 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $596 | $0 | Not Implemented |