Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
63
matching recommendationsSIC | 2361 | Girls', Children's, and Infants' Dresses, Blouses, and Shirts |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
ME0206 # 06 Y:1997 | 06 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $180 | $200 | n/a |
ME0206 # 05 Y:1997 | 05 | 1997 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $306 | $71 | n/a |
ME0206 # 04 Y:1997 | 04 | 1997 | RECOVER WASTE HEAT FROM EQUIPMENT | $367 | $150 | n/a |
ME0206 # 03 Y:1997 | 03 | 1997 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $378 | $100 | n/a |
ME0206 # 02 Y:1997 | 02 | 1997 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $2,622 | $2,500 | n/a |
ME0206 # 01 Y:1997 | 01 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $21,295 | $52,234 | n/a |
TN0524 # 04 Y:1994 | 04 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $375 | $430 | Implemented |
TN0524 # 03 Y:1994 | 03 | 1994 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $519 | $570 | Not Implemented |
TN0524 # 06 Y:1994 | 06 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $155 | $420 | Not Implemented |
TN0524 # 02 Y:1994 | 02 | 1994 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,341 | $0 | Implemented |
TN0524 # 05 Y:1994 | 05 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $286 | $318 | Implemented |
TN0524 # 01 Y:1994 | 01 | 1994 | INSTALL SPECTRAL REFLECTORS / DELAMP | $3,212 | $480 | Implemented |
TN0514 # 05 Y:1994 | 05 | 1994 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,520 | $0 | Not Implemented |
TN0514 # 02 Y:1994 | 02 | 1994 | INSULATE BARE EQUIPMENT | $6,641 | $2,168 | Implemented |
TN0514 # 03 Y:1994 | 03 | 1994 | INSTALL / REPAIR INSULATION ON STEAM LINES | $3,001 | $1,750 | Implemented |
TN0514 # 01 Y:1994 | 01 | 1994 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $28,698 | $23,000 | Implemented |
TN0514 # 04 Y:1994 | 04 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $13,643 | $2,700 | Implemented |
TN0509 # 01 Y:1994 | 01 | 1994 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,997 | $3,720 | Implemented |
TN0509 # 04 Y:1994 | 04 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $504 | $400 | Implemented |
TN0509 # 02 Y:1994 | 02 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,310 | $810 | Implemented |
TN0509 # 03 Y:1994 | 03 | 1994 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,265 | $480 | Implemented |
TN0509 # 05 Y:1994 | 05 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $258 | $600 | Implemented |
CO0289 # 04 Y:1993 | 04 | 1993 | INSTALL TIMERS AND/OR THERMOSTATS | $1,540 | $750 | Implemented |
CO0289 # 03 Y:1993 | 03 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,610 | $1,800 | Implemented |
CO0289 # 02 Y:1993 | 02 | 1993 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $1,730 | $250 | Implemented |