Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
15
matching recommendationsSIC | 238 | Miscellaneous Apparel And Accessories |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UA0204 # 01 Y:2019 | 01 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $66,234 | $104,269 | Implemented |
UA0204 # 02 Y:2019 | 02 | 2019 | INSTALL OCCUPANCY SENSORS | $238 | $145 | Not Implemented |
UA0204 # 03 Y:2019 | 03 | 2019 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,219 | $250 | Implemented |
UA0204 # 04 Y:2019 | 04 | 2019 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,537 | $1,285 | Implemented |
UA0204 # 05 Y:2019 | 05 | 2019 | INSULATE BARE EQUIPMENT | $439 | $1,082 | Implemented |
UA0067 # 01 Y:2011 | 01 | 2011 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $7,432 | $120 | Implemented |
UA0067 # 02 Y:2011 | 02 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,859 | $480 | Implemented |
UA0067 # 03 Y:2011 | 03 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $726 | $1,100 | Implemented |
UA0067 # 04 Y:2011 | 04 | 2011 | USE RADIANT HEATER FOR SPOT HEATING | $6,396 | $9,456 | Not Implemented |
GT0531 # 01 Y:1994 | 01 | 1994 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,490 | $200 | Implemented |
GT0531 # 02 Y:1994 | 02 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,600 | $25,440 | Implemented |
GT0531 # 03 Y:1994 | 03 | 1994 | INSTALL OCCUPANCY SENSORS | $880 | $130 | Not Implemented |
GT0531 # 04 Y:1994 | 04 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $80 | $250 | Implemented |
GT0531 # 05 Y:1994 | 05 | 1994 | REPAIR AND ELIMINATE STEAM LEAKS | $640 | $450 | Implemented |
GT0531 # 06 Y:1994 | 06 | 1994 | REPAIR OR REPLACE STEAM TRAPS | $4,900 | $2,500 | Implemented |