Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
22
matching recommendationsSIC | 2389 | Apparel And Accessories, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DL0199 # 03 Y:2021 | 03 | 2021 | REPAIR FAULTY LOUVERS AND DAMPERS | $2,440 | $2,275 | Not Implemented |
DL0199 # 13 Y:2021 | 13 | 2021 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,579 | $2,106 | Implemented |
DL0199 # 12 Y:2021 | 12 | 2021 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $10,836 | $5,559 | Not Implemented |
DL0199 # 11 Y:2021 | 11 | 2021 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $7,626 | $20,387 | Not Implemented |
DL0199 # 10 Y:2021 | 10 | 2021 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $2,675 | $7,837 | Not Implemented |
DL0199 # 09 Y:2021 | 09 | 2021 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $988 | $3,000 | Not Implemented |
DL0199 # 08 Y:2021 | 08 | 2021 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $272 | $1,000 | Not Implemented |
DL0199 # 07 Y:2021 | 07 | 2021 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $280 | $1,170 | Not Implemented |
DL0199 # 06 Y:2021 | 06 | 2021 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $296 | $20 | Not Implemented |
DL0199 # 05 Y:2021 | 05 | 2021 | TURN OFF EQUIPMENT WHEN NOT IN USE | $341 | $805 | Not Implemented |
DL0199 # 04 Y:2021 | 04 | 2021 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $2,657 | $1,514 | Implemented |
DL0199 # 02 Y:2021 | 02 | 2021 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $1,784 | $0 | Implemented |
DL0199 # 01 Y:2021 | 01 | 2021 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,226 | $0 | Implemented |
DL0131 # 01 Y:2014 | 01 | 2014 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $10,900 | $8,500 | Not Implemented |
DL0131 # 09 Y:2014 | 09 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,970 | $700 | Implemented |
DL0131 # 08 Y:2014 | 08 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $430 | $1,400 | Not Implemented |
DL0131 # 07 Y:2014 | 07 | 2014 | INSTALL OCCUPANCY SENSORS | $850 | $200 | Not Implemented |
DL0131 # 06 Y:2014 | 06 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $520 | $1,910 | Not Implemented |
DL0131 # 05 Y:2014 | 05 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,260 | $17,852 | Not Implemented |
DL0131 # 04 Y:2014 | 04 | 2014 | INSTALL AUTOMATIC STACK DAMPER | $1,840 | $2,800 | Not Implemented |
DL0131 # 03 Y:2014 | 03 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $20,280 | $40,560 | Not Implemented |
DL0131 # 02 Y:2014 | 02 | 2014 | TREAT AND REUSE RINSE WATERS | $13,430 | $24,000 | Not Implemented |