IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

19

matching recommendations
Reset
SIC 2392 Housefurnishings, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
RU0067 # 02 Y:1989 02 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $619 $164 Implemented
RU0067 # 03 Y:1989 03 1989 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,152 $0 Implemented
RU0067 # 04 Y:1989 04 1989 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $645 $49 Implemented
RU0067 # 05 Y:1989 05 1989 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $3,637 $6,800 Not Implemented
RU0067 # 06 Y:1989 06 1989 RECOVER WASTE HEAT FROM EQUIPMENT $12,720 $53,500 Not Implemented
RU0067 # 07 Y:1989 07 1989 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,844 $500 Implemented
RU0067 # 08 Y:1989 08 1989 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $2,462 $5,460 Not Implemented
RU0067 # 01 Y:1989 01 1989 INSTALL SET-BACK TIMERS $2,936 $240 Not Implemented
ST0025 # 11 Y:1985 11 1985 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $32,119 $10,000 Not Implemented
ST0025 # 10 Y:1985 10 1985 INSTALL STORM WINDOWS AND DOORS $14,477 $8,500 Not Implemented
ST0025 # 09 Y:1985 09 1985 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $25,374 $0 Implemented
ST0025 # 08 Y:1985 08 1985 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $2,777 $1,900 Implemented
ST0025 # 07 Y:1985 07 1985 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $281 $2,200 Not Implemented
ST0025 # 06 Y:1985 06 1985 RECOVER AND REUSE COOLING WATER $700 $1,000 Implemented
ST0025 # 05 Y:1985 05 1985 ESTABLISH EQUIPMENT MAINTENANCE SCHEDULE $1,596 $0 Not Implemented
ST0025 # 04 Y:1985 04 1985 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,350 $537 Implemented
ST0025 # 03 Y:1985 03 1985 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $14,372 $1,025 Implemented
ST0025 # 02 Y:1985 02 1985 USE MINIMUM SAFE OVEN VENTILATION $3,945 $250 Not Implemented
ST0025 # 01 Y:1985 01 1985 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $7,196 $216 Implemented