Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
83
matching recommendationsSIC | 24 | Lumber And Wood Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LS2315 # 03 Y:2023 | 03 | 2023 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,010 | $915 | Implemented |
LS2315 # 04 Y:2023 | 04 | 2023 | INSTALL OCCUPANCY SENSORS | $118 | $190 | Implemented |
LS2315 # 01 Y:2023 | 01 | 2023 | INSTALL OCCUPANCY SENSORS | $5,741 | $690 | Implemented |
LS2306 # 05 Y:2023 | 05 | 2023 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,379 | $8,210 | Implemented |
LS2306 # 02 Y:2023 | 02 | 2023 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,709 | $225 | Implemented |
LS2306 # 01 Y:2023 | 01 | 2023 | INSTALL TIMERS AND/OR THERMOSTATS | $2,207 | $250 | Implemented |
LS2306 # 06 Y:2023 | 06 | 2023 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $701 | $5,608 | Implemented |
LS2306 # 04 Y:2023 | 04 | 2023 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $1,449 | $1,273 | Implemented |
LS2306 # 03 Y:2023 | 03 | 2023 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $24,953 | $19,950 | Implemented |
LL0246 # 05 Y:2006 | 05 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $456 | $280 | Implemented |
LL0246 # 04 Y:2006 | 04 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $838 | $30 | Implemented |
LL0246 # 03 Y:2006 | 03 | 2006 | USE PHOTOCELL CONTROLS | $882 | $120 | Implemented |
LL0246 # 02 Y:2006 | 02 | 2006 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $2,013 | $330 | Implemented |
LL0246 # 01 Y:2006 | 01 | 2006 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $2,380 | $400 | Implemented |
LL0241 # 08 Y:2006 | 08 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,567 | $1,700 | Implemented |
LL0241 # 13 Y:2006 | 13 | 2006 | INSULATE BARE EQUIPMENT | $280 | $409 | Implemented |
LL0241 # 10 Y:2006 | 10 | 2006 | INSULATE BARE EQUIPMENT | $1,977 | $2,653 | Implemented |
LL0241 # 07 Y:2006 | 07 | 2006 | USE PHOTOCELL CONTROLS | $3,211 | $600 | Implemented |
LL0241 # 05 Y:2006 | 05 | 2006 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $20,822 | $1,320 | Implemented |
LL0241 # 03 Y:2006 | 03 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $77,103 | $3,196 | Implemented |
LL0241 # 02 Y:2006 | 02 | 2006 | REPAIR AND ELIMINATE STEAM LEAKS | $149,914 | $3,400 | Implemented |
LL0241 # 01 Y:2006 | 01 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $178,198 | $64,440 | Implemented |
LL0237 # 08 Y:2005 | 08 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,527 | $1,930 | Implemented |
LL0237 # 03 Y:2005 | 03 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $51,555 | $15,000 | Implemented |
LL0237 # 04 Y:2005 | 04 | 2005 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $34,402 | $1,400 | Implemented |