IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

7,223

matching recommendations
Reset
SIC 24 Lumber And Wood Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OR0139 # 04 Y:1992 04 1992 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $11,685 $10,000 Implemented
OR0139 # 05 Y:1992 05 1992 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $218 $4,614 Implemented
OR0139 # 06 Y:1992 06 1992 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $10,355 $61,690 Not Implemented
AM0143 # 01 Y:1992 01 1992 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL $4,500 $19,165 Not Implemented
AM0143 # 02 Y:1992 02 1992 IMPROVE LUBRICATION PRACTICES $730 $0 Not Implemented
AM0143 # 03 Y:1992 03 1992 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $990 $0 Not Implemented
AM0143 # 04 Y:1992 04 1992 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $400 $150 Not Implemented
AM0143 # 05 Y:1992 05 1992 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $642 $477 Not Implemented
AM0143 # 06 Y:1992 06 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $130 $200 Not Implemented
AM0144 # 01 Y:1992 01 1992 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL $30,000 $0 Not Implemented
AM0144 # 02 Y:1992 02 1992 REDUCE FLUID FLOW RATES $7,610 $750 Not Implemented
AM0144 # 03 Y:1992 03 1992 OPTIMIZE PLANT POWER FACTOR $3,370 $6,000 Not Implemented
AM0144 # 04 Y:1992 04 1992 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $1,990 $0 Not Implemented
AM0144 # 05 Y:1992 05 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $423 $960 Not Implemented
AM0144 # 06 Y:1992 06 1992 INSTALL SET-BACK TIMERS $350 $0 Not Implemented
AM0144 # 07 Y:1992 07 1992 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $340 $300 Not Implemented
AM0144 # 08 Y:1992 08 1992 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $260 $510 Not Implemented
OR0138 # 01 Y:1992 01 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $785 $0 Not Implemented
OR0138 # 02 Y:1992 02 1992 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $3,014 $0 Not Implemented
OR0138 # 03 Y:1992 03 1992 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $500 $651 Implemented
OR0138 # 04 Y:1992 04 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $15,386 $0 Not Implemented
OR0138 # 05 Y:1992 05 1992 OPTIMIZE PLANT POWER FACTOR $16,934 $36,000 Implemented
OR0138 # 06 Y:1992 06 1992 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,905 $4,384 Implemented
OR0138 # 07 Y:1992 07 1992 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $514 $1,900 Not Implemented
OR0137 # 01 Y:1992 01 1992 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $538 $0 Not Implemented