Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
7,223
matching recommendationsSIC | 24 | Lumber And Wood Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0432 # 10 Y:2011 | 10 | 2011 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $762 | $1,000 | Implemented |
WV0432 # 11 Y:2011 | 11 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $694 | $0 | Not Implemented |
WV0432 # 12 Y:2011 | 12 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $207 | $25 | Implemented |
OR0570 # 01 Y:2011 | 01 | 2011 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $19,863 | $1,120 | Implemented |
OR0570 # 02 Y:2011 | 02 | 2011 | UPGRADE CONTROLS ON COMPRESSORS | $6,640 | $2,250 | Not Implemented |
OR0570 # 03 Y:2011 | 03 | 2011 | UPGRADE CONTROLS ON COMPRESSORS | $21,600 | $12,010 | Not Implemented |
OR0570 # 04 Y:2011 | 04 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $26,900 | $17,900 | Not Implemented |
OR0570 # 05 Y:2011 | 05 | 2011 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $983 | $1,000 | Not Implemented |
OR0570 # 06 Y:2011 | 06 | 2011 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $695 | $750 | Not Implemented |
OR0570 # 07 Y:2011 | 07 | 2011 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $157,400 | $191,000 | Not Implemented |
OR0570 # 08 Y:2011 | 08 | 2011 | MAKE A NEW BY-PRODUCT | $91,432 | $156,000 | Not Implemented |
OR0570 # 09 Y:2011 | 09 | 2011 | REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL | $543,000 | $1,200,000 | Not Implemented |
OR0570 # 10 Y:2011 | 10 | 2011 | INSTALL SKYLIGHTS | $2,930 | $9,050 | Not Implemented |
OR0570 # 11 Y:2011 | 11 | 2011 | OPTIMIZE PLANT POWER FACTOR | $10,100 | $51,900 | Not Implemented |
WV0430 # 01 Y:2011 | 01 | 2011 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $70,581 | $20,000 | Not Implemented |
WV0430 # 02 Y:2011 | 02 | 2011 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $43,659 | $3,500 | Implemented |
WV0430 # 03 Y:2011 | 03 | 2011 | USE RADIANT HEATER FOR SPOT HEATING | $39,290 | $65,840 | Not Implemented |
WV0430 # 04 Y:2011 | 04 | 2011 | UPGRADE CONTROLS ON COMPRESSORS | $34,733 | $26,650 | Implemented |
WV0430 # 05 Y:2011 | 05 | 2011 | MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT | $28,475 | $76,200 | Not Implemented |
WV0430 # 06 Y:2011 | 06 | 2011 | OPTIMIZE PLANT POWER FACTOR | $25,696 | $37,805 | Not Implemented |
WV0430 # 07 Y:2011 | 07 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $19,692 | $37,460 | Implemented |
WV0430 # 08 Y:2011 | 08 | 2011 | COMBINE UTILITY METERS | $10,426 | $20,000 | Not Implemented |
WV0430 # 09 Y:2011 | 09 | 2011 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $8,265 | $57,400 | Not Implemented |
MS0374 # 01 Y:2011 | 01 | 2011 | USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR | $57,503 | $375,001 | Not Implemented |
MS0374 # 02 Y:2011 | 02 | 2011 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $13,956 | $12,825 | Implemented |