Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
38
matching recommendationsSIC | 2426 | Hardwood Dimension & Flooring Mills |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0126 # 06 Y:1997 | 06 | 1997 | REPLACE ELECTRIC MOTORS WITH BACK PRESSURE STEAM TURBINES AND USE EXHAUST STEAM FOR PROCESS HEAT | $33,895 | $56,800 | Not Implemented |
NC0126 # 01 Y:1997 | 01 | 1997 | CONDENSE OPERATION INTO ONE BUILDING | $152,949 | $49,000 | Not Implemented |
NC0126 # 05 Y:1997 | 05 | 1997 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $2,042 | $5,200 | Implemented |
NC0126 # 04 Y:1997 | 04 | 1997 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $6,974 | $17,620 | Not Implemented |
NC0126 # 03 Y:1997 | 03 | 1997 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $13,564 | $12,000 | Not Implemented |
NC0126 # 02 Y:1997 | 02 | 1997 | REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL | $6,290 | $18,100 | Not Implemented |
NC0126 # 10 Y:1997 | 10 | 1997 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $35,268 | $9,150 | Not Implemented |
NC0126 # 07 Y:1997 | 07 | 1997 | USE FOSSIL FUEL POWERED GENERATOR DURING PEAK DEMAND PERIODS | $66,010 | $220,000 | Not Implemented |
NC0126 # 08 Y:1997 | 08 | 1997 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $962 | $2,400 | Not Implemented |
NC0126 # 09 Y:1997 | 09 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $888 | $1,314 | Implemented |
NC0126 # 13 Y:1997 | 13 | 1997 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $322 | $240 | Not Implemented |
NC0126 # 12 Y:1997 | 12 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $143 | $180 | Implemented |
NC0126 # 11 Y:1997 | 11 | 1997 | ADD AREA LIGHTING SWITCHES | $3,197 | $2,420 | Not Implemented |