Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,511
matching recommendationsSIC | 243 | Millwork, Plywood & Structural |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0051 # 04 Y:1993 | 04 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $544 | $80 | Not Implemented |
SD0051 # 05 Y:1993 | 05 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $102 | $0 | Implemented |
SD0051 # 06 Y:1993 | 06 | 1993 | INSTALL SET-BACK TIMERS | $771 | $1,080 | Implemented |
SD0051 # 07 Y:1993 | 07 | 1993 | INSTALL SPECTRAL REFLECTORS / DELAMP | $1,314 | $2,080 | Implemented |
SD0051 # 08 Y:1993 | 08 | 1993 | USE PHOTOCELL CONTROLS | $907 | $1,715 | Not Implemented |
UF0056 # 07 Y:1993 | 07 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,794 | $1,450 | Implemented |
UF0056 # 06 Y:1993 | 06 | 1993 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,758 | $6,000 | Not Implemented |
UF0056 # 05 Y:1993 | 05 | 1993 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,417 | $680 | Implemented |
UF0056 # 04 Y:1993 | 04 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,682 | $6,727 | Implemented |
UF0056 # 03 Y:1993 | 03 | 1993 | OPTIMIZE PLANT POWER FACTOR | $9,259 | $15,000 | Not Implemented |
UF0056 # 02 Y:1993 | 02 | 1993 | INSTALL SPECTRAL REFLECTORS / DELAMP | $560 | $1,620 | Not Implemented |
UF0056 # 01 Y:1993 | 01 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,372 | $350 | Implemented |
UF0051 # 01 Y:1993 | 01 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,311 | $6,715 | Not Implemented |
UF0051 # 02 Y:1993 | 02 | 1993 | INSTALL SPECTRAL REFLECTORS / DELAMP | $1,536 | $5,520 | Not Implemented |
UF0051 # 03 Y:1993 | 03 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,768 | $7,202 | Implemented |
UF0051 # 04 Y:1993 | 04 | 1993 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $10,415 | $9,640 | Not Implemented |
UF0051 # 05 Y:1993 | 05 | 1993 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,119 | $2,875 | Not Implemented |
UF0051 # 06 Y:1993 | 06 | 1993 | USE POWER DURING OFF-PEAK PERIODS | $54,774 | $0 | Not Implemented |
OR0159 # 01 Y:1992 | 01 | 1992 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,183 | $670 | Implemented |
OR0159 # 02 Y:1992 | 02 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,001 | $4,750 | Implemented |
OR0159 # 03 Y:1992 | 03 | 1992 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,062 | $4,140 | Implemented |
OR0159 # 04 Y:1992 | 04 | 1992 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,364 | $928 | Implemented |
OR0159 # 05 Y:1992 | 05 | 1992 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $499 | $0 | Not Implemented |
OR0159 # 06 Y:1992 | 06 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $413 | $1,810 | Not Implemented |
OR0159 # 07 Y:1992 | 07 | 1992 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $10,380 | $9,000 | Implemented |