Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
27
matching recommendationsSIC | 243 | Millwork, Plywood & Structural |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0182 # 03 Y:1983 | 03 | 1983 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $140 | $322 | Not Implemented |
TN0182 # 02 Y:1983 | 02 | 1983 | AIR CONDITION ONLY SPACE NECESSARY | $500 | $1,000 | Not Implemented |
TN0182 # 01 Y:1983 | 01 | 1983 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $800 | $2,850 | Not Implemented |
KU0107 # 09 Y:1983 | 09 | 1983 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,228 | $1,389 | Not Implemented |
KU0107 # 08 Y:1983 | 08 | 1983 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $156 | $150 | Not Implemented |
KU0107 # 07 Y:1983 | 07 | 1983 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $402 | $0 | Implemented |
KU0107 # 06 Y:1983 | 06 | 1983 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $565 | $210 | Implemented |
KU0107 # 05 Y:1983 | 05 | 1983 | INCREASE EFFICIENCY OF TRUCKS | $171 | $600 | Not Implemented |
KU0107 # 04 Y:1983 | 04 | 1983 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $223 | $56 | Implemented |
KU0107 # 03 Y:1983 | 03 | 1983 | INSTALL AUTOMATIC STACK DAMPER | $372 | $300 | Implemented |
KU0107 # 02 Y:1983 | 02 | 1983 | USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD | $931 | $1,100 | Implemented |
KU0107 # 01 Y:1983 | 01 | 1983 | BURN WOOD BY-PRODUCTS FOR HEAT | $7,703 | $10,000 | Implemented |
KU0107 # 10 Y:1983 | 10 | 1983 | REPLACE BROKEN WINDOWS AND/OR WINDOW SASH | $275 | $65 | Implemented |
KU0107 # 11 Y:1983 | 11 | 1983 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $41 | $0 | Implemented |
UD0096 # 03 Y:1983 | 03 | 1983 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,923 | $630 | Not Implemented |
UD0096 # 01 Y:1983 | 01 | 1983 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $31,335 | $45,000 | Not Implemented |
UD0096 # 02 Y:1983 | 02 | 1983 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,706 | $0 | Not Implemented |
UD0096 # 04 Y:1983 | 04 | 1983 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $476 | $0 | Not Implemented |
KU0072 # 08 Y:1983 | 08 | 1983 | INSTALL AUTOMATIC STACK DAMPER | $617 | $700 | Not Implemented |
KU0072 # 07 Y:1983 | 07 | 1983 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $537 | $200 | Not Implemented |
KU0072 # 06 Y:1983 | 06 | 1983 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $269 | $200 | Not Implemented |
KU0072 # 05 Y:1983 | 05 | 1983 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $2,160 | $837 | Not Implemented |
KU0072 # 04 Y:1983 | 04 | 1983 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $1,843 | $0 | Not Implemented |
KU0072 # 03 Y:1983 | 03 | 1983 | INSTALL TIMERS AND/OR THERMOSTATS | $3,142 | $100 | Not Implemented |
KU0072 # 02 Y:1983 | 02 | 1983 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $6,501 | $1,660 | Not Implemented |