Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
62
matching recommendationsSIC | 2431 | Millwork |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0381 # 01 Y:2008 | 01 | 2008 | INSTALL TIMERS AND/OR THERMOSTATS | $70,581 | $24,000 | Not Implemented |
WV0381 # 14 Y:2008 | 14 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,586 | $0 | Not Implemented |
WV0381 # 13 Y:2008 | 13 | 2008 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $4,036 | $38,700 | Not Implemented |
WV0381 # 12 Y:2008 | 12 | 2008 | INSTALL SET-BACK TIMERS | $6,981 | $1,150 | Implemented |
WV0381 # 11 Y:2008 | 11 | 2008 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $7,681 | $10,660 | Implemented |
WV0381 # 10 Y:2008 | 10 | 2008 | DEVELOP A REPAIR/REPLACE POLICY | $8,516 | $1,250 | Not Implemented |
WV0381 # 09 Y:2008 | 09 | 2008 | COMBINE UTILITY METERS | $10,426 | $20,000 | Not Implemented |
WV0381 # 08 Y:2008 | 08 | 2008 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $21,259 | $25,425 | Implemented |
WV0381 # 07 Y:2008 | 07 | 2008 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $25,395 | $2,100 | Implemented |
WV0381 # 06 Y:2008 | 06 | 2008 | OPTIMIZE PLANT POWER FACTOR | $25,696 | $34,550 | Implemented |
WV0381 # 05 Y:2008 | 05 | 2008 | MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT | $28,475 | $76,200 | Implemented |
WV0381 # 04 Y:2008 | 04 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $29,296 | $19,992 | Implemented |
WV0381 # 03 Y:2008 | 03 | 2008 | ELIMINATE COOLING OF PROCESS STREAMS WHICH SUBSEQUENTLY MUST BE HEATED AND VICE VERSA | $53,901 | $12,000 | Not Implemented |
WV0381 # 02 Y:2008 | 02 | 2008 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $43,659 | $3,500 | Not Implemented |
WV0381 # 16 Y:2008 | 16 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,867 | $1,300 | Not Implemented |
WV0381 # 15 Y:2008 | 15 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,545 | $2,940 | Not Implemented |
UD0544 # 10 Y:1998 | 10 | 1998 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $769 | $0 | Implemented |
UD0544 # 01 Y:1998 | 01 | 1998 | USE MORE EFFICIENT ADHESIVE APPLICATORS | $15,189 | $500 | Implemented |
UD0544 # 02 Y:1998 | 02 | 1998 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $13,720 | $800 | Not Implemented |
UD0544 # 03 Y:1998 | 03 | 1998 | TURN OFF EQUIPMENT WHEN NOT IN USE | $8,392 | $0 | Implemented |
UD0544 # 04 Y:1998 | 04 | 1998 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $6,427 | $1,000 | Implemented |
UD0544 # 05 Y:1998 | 05 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,145 | $1,000 | Implemented |
UD0544 # 06 Y:1998 | 06 | 1998 | REPAIR FAULTY LOUVERS AND DAMPERS | $2,092 | $400 | Implemented |
UD0544 # 07 Y:1998 | 07 | 1998 | PROVIDE PROPER MAINTENANCE OF MOTOR DRIVEN EQUIPMENT | $2,054 | $0 | Implemented |
UD0544 # 08 Y:1998 | 08 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,695 | $3,472 | Not Implemented |