Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,179

matching recommendations
Reset
SIC 2431 Millwork
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UF0327 # 07 Y:2003 07 2003 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $39,320 $10,726 Not Implemented
UF0327 # 08 Y:2003 08 2003 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $21,592 $110,000 Implemented
UF0327 # 09 Y:2003 09 2003 INSTALL EQUIPMENT TO MOVE PRODUCT $15,228 $5,300 Implemented
UF0327 # 10 Y:2003 10 2003 INSTALL SYSTEM TO COLLECT SCRAP $7,800 $780 Implemented
UF0327 # 11 Y:2003 11 2003 IMPROVE SPACE COMFORT CONDITIONING $26,498 $49,051 Not Implemented
UU0033 # 01 Y:2002 01 2002 OPTIMIZE PLANT POWER FACTOR $4,720 $4,461 Implemented
UU0033 # 02 Y:2002 02 2002 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $688 $1,688 Implemented
UU0033 # 03 Y:2002 03 2002 USE SYNTHETIC LUBRICANT $2,551 $1,000 Implemented
UU0033 # 04 Y:2002 04 2002 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,484 $0 Implemented
UU0033 # 05 Y:2002 05 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,217 $11,405 Not Implemented
UU0033 # 06 Y:2002 06 2002 RECOVER WASTE HEAT FROM EQUIPMENT $1,481 $1,158 Not Implemented
UU0033 # 07 Y:2002 07 2002 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,422 $116 Implemented
UU0033 # 08 Y:2002 08 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,557 $235 Implemented
MI0034 # 01 Y:2002 01 2002 CLEAR AND RENT EXISTING SPACE $114,920 $10,000 Not Implemented
MI0034 # 02 Y:2002 02 2002 CLEAR AND RENT EXISTING SPACE $38,760 $120 Not Implemented
MI0034 # 03 Y:2002 03 2002 $49,218 $64 Not Implemented
MI0034 # 04 Y:2002 04 2002 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT $31,945 $4,500 Not Implemented
MI0034 # 05 Y:2002 05 2002 CLEAR AND RENT EXISTING SPACE $23,880 $120 Not Implemented
MI0034 # 06 Y:2002 06 2002 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $7,201 $6,000 Not Implemented
MI0034 # 07 Y:2002 07 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,913 $113 Not Implemented
OK0631 # 01 Y:2001 01 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $15,487 $400 Implemented
OK0631 # 02 Y:2001 02 2001 INSULATE BARE EQUIPMENT $13,831 $8,000 Implemented
OK0631 # 03 Y:2001 03 2001 ADD AREA LIGHTING SWITCHES $1,991 $194 Implemented
OK0631 # 04 Y:2001 04 2001 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,478 $6,067 Implemented
OK0631 # 05 Y:2001 05 2001 INSTALL EQUIPMENT TO MOVE PRODUCT $174,720 $364,000 Implemented