Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,179
matching recommendationsSIC | 2431 | Millwork |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
ND0312 # 08 Y:1998 | 08 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $678 | $2,967 | Not Implemented |
ND0312 # 09 Y:1998 | 09 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $358 | $660 | Not Implemented |
ND0312 # 10 Y:1998 | 10 | 1998 | INSTALL OCCUPANCY SENSORS | $249 | $720 | Not Implemented |
ND0312 # 11 Y:1998 | 11 | 1998 | TURN OFF EQUIPMENT WHEN NOT IN USE | $34 | $0 | Implemented |
OK0547 # 01 Y:1998 | 01 | 1998 | INSTALL SET-BACK TIMERS | $400 | $100 | n/a |
OK0547 # 02 Y:1998 | 02 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,951 | $4,900 | n/a |
OK0547 # 03 Y:1998 | 03 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,865 | $9,005 | n/a |
OK0547 # 04 Y:1998 | 04 | 1998 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $151 | $0 | n/a |
OK0547 # 05 Y:1998 | 05 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $803 | $1,000 | n/a |
OK0547 # 06 Y:1998 | 06 | 1998 | ELIMINATE SHIFT | $9,629 | $4,944 | n/a |
OK0547 # 07 Y:1998 | 07 | 1998 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $1,400 | $4,000 | n/a |
SD0198 # 01 Y:1998 | 01 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,243 | $9,800 | Implemented |
SD0198 # 02 Y:1998 | 02 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,483 | $550 | Implemented |
SD0198 # 03 Y:1998 | 03 | 1998 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $23,506 | $7,400 | Not Implemented |
SD0198 # 04 Y:1998 | 04 | 1998 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $588 | $207 | Implemented |
SD0198 # 05 Y:1998 | 05 | 1998 | REMOVE UNNEEDED SERVICE LINES TO ELIMINATE POTENTIAL LEAKS | $866 | $125 | Implemented |
SD0198 # 06 Y:1998 | 06 | 1998 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,358 | $17,300 | Not Implemented |
SD0198 # 07 Y:1998 | 07 | 1998 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,809 | $14,150 | Not Implemented |
SD0198 # 08 Y:1998 | 08 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $259 | $916 | Implemented |
SD0198 # 09 Y:1998 | 09 | 1998 | INSTALL SPECTRAL REFLECTORS / DELAMP | $178 | $180 | Not Implemented |
SD0198 # 10 Y:1998 | 10 | 1998 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $2,600 | $8,500 | Implemented |
SD0198 # 11 Y:1998 | 11 | 1998 | MAKE A NEW BY-PRODUCT | $5,100 | $0 | Not Implemented |
SD0198 # 12 Y:1998 | 12 | 1998 | USE LESS WASTEFUL PACKAGING | $5,600 | $0 | Not Implemented |
SD0198 # 13 Y:1998 | 13 | 1998 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $2,550 | $0 | Not Implemented |
SD0198 # 14 Y:1998 | 14 | 1998 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $4,674 | $3,980 | Not Implemented |