Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
64
matching recommendationsSIC | 2431 | Millwork |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0334 # 01 Y:1998 | 01 | 1998 | CONDENSE OPERATION INTO ONE BUILDING | $1,080,150 | $1,000,000 | Implemented |
OR0334 # 09 Y:1998 | 09 | 1998 | REGENERATE CLEANING SOLVENT ON-SITE AND REUSE | $1,146 | $350 | Not Implemented |
OR0334 # 08 Y:1998 | 08 | 1998 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $5,250 | $0 | Implemented |
OR0334 # 07 Y:1998 | 07 | 1998 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,890 | $0 | Implemented |
OR0334 # 06 Y:1998 | 06 | 1998 | UPGRADE CONTROLS ON COMPRESSORS | $14,409 | $9,600 | Implemented |
OR0334 # 05 Y:1998 | 05 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,499 | $6,000 | Implemented |
OR0334 # 04 Y:1998 | 04 | 1998 | OPTIMIZE PLANT POWER FACTOR | $15,977 | $44,400 | Not Implemented |
OR0334 # 03 Y:1998 | 03 | 1998 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $48,900 | $220,000 | Not Implemented |
OR0334 # 02 Y:1998 | 02 | 1998 | INSTALL EQUIPMENT TO MOVE PRODUCT | $14,550 | $31,520 | Implemented |
ND0312 # 09 Y:1998 | 09 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $358 | $660 | Not Implemented |
ND0312 # 03 Y:1998 | 03 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,624 | $7,151 | Not Implemented |
ND0312 # 02 Y:1998 | 02 | 1998 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $3,382 | $7,920 | Not Implemented |
ND0312 # 01 Y:1998 | 01 | 1998 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $8,855 | $7,500 | Not Implemented |
ND0312 # 04 Y:1998 | 04 | 1998 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $2,457 | $3,200 | Not Implemented |
ND0312 # 06 Y:1998 | 06 | 1998 | CONVERT TO AQUEOUS CLEANING SYSTEM | $1,191 | $100 | Not Implemented |
ND0312 # 07 Y:1998 | 07 | 1998 | DEMOLISH OLD BUILDING TO REDUCE TAX AND INSURANCE BILLS | $1,072 | $250 | Not Implemented |
ND0312 # 08 Y:1998 | 08 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $678 | $2,967 | Not Implemented |
ND0312 # 05 Y:1998 | 05 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $513 | $150 | Implemented |
ND0312 # 10 Y:1998 | 10 | 1998 | INSTALL OCCUPANCY SENSORS | $249 | $720 | Not Implemented |
ND0312 # 11 Y:1998 | 11 | 1998 | TURN OFF EQUIPMENT WHEN NOT IN USE | $34 | $0 | Implemented |
OK0547 # 06 Y:1998 | 06 | 1998 | ELIMINATE SHIFT | $9,629 | $4,944 | n/a |
OK0547 # 04 Y:1998 | 04 | 1998 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $151 | $0 | n/a |
OK0547 # 05 Y:1998 | 05 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $803 | $1,000 | n/a |
OK0547 # 07 Y:1998 | 07 | 1998 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $1,400 | $4,000 | n/a |
OK0547 # 02 Y:1998 | 02 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,951 | $4,900 | n/a |