Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,425
matching recommendationsSIC | 249 | Miscellaneous Wood Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0024 # 01 Y:1985 | 01 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $12,774 | $78 | Implemented |
CO0024 # 02 Y:1985 | 02 | 1985 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,110 | $15,000 | Implemented |
CO0024 # 03 Y:1985 | 03 | 1985 | REPAIR AND ELIMINATE STEAM LEAKS | $5,315 | $2,000 | Implemented |
CO0024 # 04 Y:1985 | 04 | 1985 | INSULATE BARE EQUIPMENT | $454 | $1,800 | Not Implemented |
CO0024 # 05 Y:1985 | 05 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $242 | $100 | Not Implemented |
CO0024 # 06 Y:1985 | 06 | 1985 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $10,838 | $900 | Implemented |
LT0019 # 01 Y:1985 | 01 | 1985 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $277 | $8 | Not Implemented |
LT0019 # 02 Y:1985 | 02 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $482 | $444 | Not Implemented |
TN0227 # 01 Y:1984 | 01 | 1984 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $7,818 | $3,675 | Not Implemented |
TN0227 # 02 Y:1984 | 02 | 1984 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $12,425 | $0 | Implemented |
TN0227 # 03 Y:1984 | 03 | 1984 | INSULATE BARE EQUIPMENT | $3,155 | $5,000 | Implemented |
TN0227 # 04 Y:1984 | 04 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $755 | $0 | Implemented |
TN0227 # 05 Y:1984 | 05 | 1984 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,656 | $25 | Implemented |
TN0227 # 06 Y:1984 | 06 | 1984 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $200 | $0 | Not Implemented |
TN0227 # 07 Y:1984 | 07 | 1984 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $67 | $0 | Implemented |
TN0179 # 01 Y:1983 | 01 | 1983 | OPTIMIZE PLANT POWER FACTOR | $8,400 | $5,000 | Implemented |
TN0179 # 02 Y:1983 | 02 | 1983 | INSULATE BARE EQUIPMENT | $2,291 | $5,700 | Implemented |
TN0179 # 03 Y:1983 | 03 | 1983 | USE SOLAR HEAT TO HEAT WATER | $826 | $24,000 | Implemented |
GT0135 # 01 Y:1982 | 01 | 1982 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $14,899 | $39,200 | Not Implemented |
GT0135 # 02 Y:1982 | 02 | 1982 | UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING | $2,580 | $3,250 | Not Implemented |
GT0135 # 03 Y:1982 | 03 | 1982 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,558 | $100 | Not Implemented |
GT0135 # 04 Y:1982 | 04 | 1982 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,471 | $1,577 | Not Implemented |
GT0135 # 05 Y:1982 | 05 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,473 | $333 | Not Implemented |
GT0135 # 06 Y:1982 | 06 | 1982 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $1,131 | $600 | Not Implemented |
GT0135 # 07 Y:1982 | 07 | 1982 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $440 | $250 | Not Implemented |