Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
39
matching recommendationsSIC | 249 | Miscellaneous Wood Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LS2420 # 03 Y:2024 | 03 | 2024 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $16,356 | $15,100 | n/a |
LS2420 # 02 Y:2024 | 02 | 2024 | INSTALL TIMERS AND/OR THERMOSTATS | $1,025 | $25 | n/a |
LS2420 # 01 Y:2024 | 01 | 2024 | LEVEL ZERO – INSTALL CONTROL SYSTEMS FOR EXISTING EQUIPMENT | $7,485 | $0 | n/a |
LS2420 # 06 Y:2024 | 06 | 2024 | INSTALL ISOLATION TRANSFORMER ON ADJUSTABLE FREQUENCY DRIVE | $11,877 | $51,800 | n/a |
LS2420 # 04 Y:2024 | 04 | 2024 | UPGRADE CONTROLS ON COMPRESSORS | $9,307 | $21,000 | n/a |
LS2420 # 05 Y:2024 | 05 | 2024 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $24,642 | $68,828 | n/a |
LL0237 # 08 Y:2005 | 08 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,527 | $1,930 | Implemented |
LL0237 # 07 Y:2005 | 07 | 2005 | INSTALL OCCUPANCY SENSORS | $1,195 | $0 | Not Implemented |
LL0237 # 06 Y:2005 | 06 | 2005 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $13,071 | $0 | Not Implemented |
LL0237 # 05 Y:2005 | 05 | 2005 | USE PHOTOCELL CONTROLS | $22,793 | $0 | Not Implemented |
LL0237 # 04 Y:2005 | 04 | 2005 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $34,402 | $1,400 | Implemented |
LL0237 # 03 Y:2005 | 03 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $51,555 | $15,000 | Implemented |
LL0237 # 02 Y:2005 | 02 | 2005 | INSULATE BARE EQUIPMENT | $46,200 | $2,600 | Implemented |
LL0237 # 01 Y:2005 | 01 | 2005 | BURN WASTE TO PRODUCE STEAM TO DRIVE A STEAM TURBINE GENERATOR SET AND USE STEAM EXHAUST FOR HEAT | $3,092,622 | $0 | Not Implemented |
LL0238 # 02 Y:2005 | 02 | 2005 | REPAIR AND ELIMINATE STEAM LEAKS | $47,162 | $3,000 | Implemented |
LL0238 # 10 Y:2005 | 10 | 2005 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $7,299 | $1,000 | Implemented |
LL0238 # 09 Y:2005 | 09 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $730 | $0 | Not Implemented |
LL0238 # 08 Y:2005 | 08 | 2005 | INSTALL OCCUPANCY SENSORS | $285 | $0 | Not Implemented |
LL0238 # 07 Y:2005 | 07 | 2005 | USE PHOTOCELL CONTROLS | $354 | $0 | Not Implemented |
LL0238 # 06 Y:2005 | 06 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $480 | $0 | Not Implemented |
LL0238 # 05 Y:2005 | 05 | 2005 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,065 | $0 | Not Implemented |
LL0238 # 04 Y:2005 | 04 | 2005 | INSULATE BARE EQUIPMENT | $2,207 | $500 | Implemented |
LL0238 # 03 Y:2005 | 03 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,179 | $1,500 | Implemented |
LL0238 # 01 Y:2005 | 01 | 2005 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $60,523 | $0 | Not Implemented |
LT0131 # 01 Y:1988 | 01 | 1988 | RECOVER WASTE HEAT FROM EQUIPMENT | $800 | $2,400 | Implemented |