Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,700

matching recommendations
Reset
SIC 25 Furniture And Fixtures
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
GT0505 # 01 Y:1993 01 1993 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $1,090 $1,600 Implemented
GT0505 # 02 Y:1993 02 1993 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $7,370 $6,400 Implemented
GT0505 # 03 Y:1993 03 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,250 $830 Implemented
GT0505 # 07 Y:1993 07 1993 USE RADIANT HEATER FOR SPOT HEATING $11,700 $80,000 Implemented
AR0011 # 01 Y:1993 01 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,614 $2,225 Implemented
AR0011 # 03 Y:1993 03 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,990 $250 Implemented
WI0190 # 01 Y:1993 01 1993 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $21,567 $800 Implemented
WI0190 # 02 Y:1993 02 1993 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $5,245 $500 Implemented
WI0190 # 03 Y:1993 03 1993 USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR $1,049 $500 Implemented
WI0190 # 09 Y:1993 09 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,892 $2,909 Implemented
WI0190 # 10 Y:1993 10 1993 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $2,495 $450 Implemented
WI0190 # 11 Y:1993 11 1993 INSTALL OCCUPANCY SENSORS $1,165 $225 Implemented
WI0190 # 13 Y:1993 13 1993 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,124 $320 Implemented
OK0414 # 02 Y:1993 02 1993 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,531 $200 Implemented
OK0414 # 03 Y:1993 03 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,446 $0 Implemented
OK0414 # 04 Y:1993 04 1993 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,058 $3,889 Implemented
NC0007 # 05 Y:1993 05 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $770 $450 Implemented
NC0007 # 06 Y:1993 06 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,702 $10,980 Implemented
NC0007 # 07 Y:1993 07 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,177 $2,106 Implemented
NC0007 # 08 Y:1993 08 1993 INSTALL TURBULATORS $8,700 $1,500 Implemented
NC0009 # 01 Y:1993 01 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,251 $252 Implemented
NC0009 # 02 Y:1993 02 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,879 $540 Implemented
NC0009 # 04 Y:1993 04 1993 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,400 $960 Implemented
NC0009 # 06 Y:1993 06 1993 CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN $2,408 $0 Implemented
NC0010 # 01 Y:1993 01 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,824 $11,100 Implemented