Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Missouri, Rolla
Assessment Year 1994
Principal Product Office Filing Supplies
NAICS n/a
SIC 2522 - Office Furniture, Except Wood
Sales $50,000,000-$100,000,000
# of Employees 400
Plant Area (Sq.Ft.) 326,000
Annual Production 84,000,000 Pounds
Production Hrs. Annual 6,300
Location (State) MO
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $385,008 7,169,695 kWh $0.05
Natural Gas $7,285 1,584 MMBtu $4.60
LPG $26,930 3,913 MMBtu $6.88
TOTAL ENERGY COSTS $419,223
RECOMMENDED SAVINGS* $105,371 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $14,518
#|Description Savings
Cost
Status Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes
$ kWh $ MMBtu $ $
01: 2.7231 USE RADIANT HEATER FOR SPOT HEATING Savings:
$56,232
Cost:
$47,580
$56,232 504,396 - - - - $56,232
504,396
kWh
-
-
MMBtu
-
-
$
02: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS Savings:
$13,754
Cost:
$17,627
$13,754 256,155 - - - - $13,754
256,155
kWh
-
-
MMBtu
-
-
$
03: 2.2511 INSULATE BARE EQUIPMENT Savings:
$1,914
Cost:
$2,341
$1,914 35,756 - - - - $1,914
35,756
kWh
-
-
MMBtu
-
-
$
04: 2.8113 PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER Savings:
$10,357
Cost:
$300
- - - - $10,357 - -
-
kWh
-
-
MMBtu
$10,357
-
$
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$5,689
Cost:
$16,563
$5,689 105,803 - - - - $5,689
105,803
kWh
-
-
MMBtu
-
-
$
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,418
Cost:
$641
$2,418 45,135 - - - - $2,418
45,135
kWh
-
-
MMBtu
-
-
$
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$277
Cost:
$728
$277 5,275 - - - - $277
5,275
kWh
-
-
MMBtu
-
-
$
08: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$5,508
Cost:
$12,224
$5,508 102,579 - - - - $5,508
102,579
kWh
-
-
MMBtu
-
-
$
09: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$1,301
Cost:
$775
$1,301 24,326 - - - - $1,301
24,326
kWh
-
-
MMBtu
-
-
$
10: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$3,211
Cost:
$3,010
$3,211 59,789 - - - - $3,211
59,789
kWh
-
-
MMBtu
-
-
$
11: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$3,088
Cost:
$250
$3,088 57,444 - - - - $3,088
57,444
kWh
-
-
MMBtu
-
-
$
12: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT Savings:
$1,162
Cost:
$1,547
$1,831 33,998 $(-669) (-145) - - $1,831
33,998
kWh
$(-669)
(-145)
MMBtu
-
-
$
13: 2.6121 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED Savings:
$460
Cost:
$40
$460 8,499 - - - - $460
8,499
kWh
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$105,371
Cost:
$103,626
$95,683 1,239,155 $(-669) (-145) $10,357 - $95,683
1,239,155
kWh
$(-669)
(-145)
MMBtu
$10,357
-
$
TOTAL IMPLEMENTED Savings:
$14,518
Cost:
$23,304
$15,187 282,825 $(-669) (-145) - - $15,187
282,825
kWh
$(-669)
(-145)
MMBtu
-
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes