Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
26
matching recommendationsSIC | 25 | Furniture And Fixtures |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0517 # 02 Y:2014 | 02 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,892 | $693 | Implemented |
IA0517 # 01 Y:2014 | 01 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,210 | $775 | Implemented |
IA0393 # 08 Y:2006 | 08 | 2006 | MODIFY STARTUP/SHUTDOWN TIMES | $5,715 | $0 | Implemented |
IA0393 # 07 Y:2006 | 07 | 2006 | INSTALL OCCUPANCY SENSORS | $636 | $1,155 | Implemented |
IA0393 # 06 Y:2006 | 06 | 2006 | ADD AREA LIGHTING SWITCHES | $1,508 | $1,200 | Implemented |
IA0393 # 05 Y:2006 | 05 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,479 | $16,536 | Implemented |
IA0393 # 04 Y:2006 | 04 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,978 | $0 | Implemented |
IA0393 # 03 Y:2006 | 03 | 2006 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $762 | $0 | Implemented |
IA0393 # 01 Y:2006 | 01 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,020 | $541 | Implemented |
IA0106 # 04 Y:1995 | 04 | 1995 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $460 | $25 | Implemented |
IA0106 # 09 Y:1995 | 09 | 1995 | USE A DIFFERENT OR RECYCLED RAW MATERIAL | $969 | $0 | Implemented |
IA0106 # 08 Y:1995 | 08 | 1995 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $4,875 | $8,480 | Implemented |
IA0106 # 07 Y:1995 | 07 | 1995 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $28,368 | $1,100 | Implemented |
IA0106 # 03 Y:1995 | 03 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $736 | $25 | Implemented |
IA0106 # 02 Y:1995 | 02 | 1995 | USE SYNTHETIC LUBRICANT | $951 | $2,159 | Implemented |
IA0106 # 01 Y:1995 | 01 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,241 | $554 | Implemented |
IA0077 # 05 Y:1994 | 05 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $609 | $100 | Implemented |
IA0077 # 02 Y:1994 | 02 | 1994 | OPTIMIZE PLANT POWER FACTOR | $5,776 | $13,208 | Implemented |
IA0052 # 07 Y:1993 | 07 | 1993 | INSTALL OCCUPANCY SENSORS | $2,044 | $2,646 | Implemented |
IA0052 # 06 Y:1993 | 06 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,629 | $518 | Implemented |
IA0051 # 02 Y:1993 | 02 | 1993 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $324 | $261 | Implemented |
IA0051 # 09 Y:1993 | 09 | 1993 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $188 | $20 | Implemented |
IA0051 # 08 Y:1993 | 08 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,028 | $320 | Implemented |
IA0051 # 06 Y:1993 | 06 | 1993 | INSTALL OCCUPANCY SENSORS | $1,750 | $1,890 | Implemented |
IA0051 # 04 Y:1993 | 04 | 1993 | INSTALL SET-BACK TIMERS | $10,125 | $0 | Implemented |