Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,525
matching recommendationsSIC | 25 | Furniture And Fixtures |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MS0011 # 03 Y:1994 | 03 | 1994 | OPTIMIZE PLANT POWER FACTOR | $6,195 | $9,840 | Not Implemented |
MS0011 # 04 Y:1994 | 04 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,244 | $13,000 | Implemented |
MS0011 # 05 Y:1994 | 05 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,962 | $5,333 | Not Implemented |
MS0011 # 06 Y:1994 | 06 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $206 | $102 | Implemented |
NC0035 # 01 Y:1994 | 01 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,391 | $1,620 | Implemented |
NC0035 # 02 Y:1994 | 02 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,132 | $700 | Not Implemented |
NC0035 # 03 Y:1994 | 03 | 1994 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,131 | $500 | Not Implemented |
NC0035 # 04 Y:1994 | 04 | 1994 | TURN OFF EQUIPMENT WHEN NOT IN USE | $824 | $0 | Implemented |
NC0035 # 05 Y:1994 | 05 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,711 | $1,085 | Not Implemented |
NC0035 # 06 Y:1994 | 06 | 1994 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $664 | $820 | Not Implemented |
NC0035 # 07 Y:1994 | 07 | 1994 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $7,987 | $17,200 | Not Implemented |
NC0035 # 08 Y:1994 | 08 | 1994 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,639 | $2,000 | Not Implemented |
NC0035 # 09 Y:1994 | 09 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,960 | $9,280 | Implemented |
NC0035 # 10 Y:1994 | 10 | 1994 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $6,023 | $3,650 | Not Implemented |
SD0091 # 01 Y:1994 | 01 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,122 | $1,270 | Implemented |
SD0091 # 02 Y:1994 | 02 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,546 | $525 | Implemented |
SD0091 # 03 Y:1994 | 03 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,073 | $3,076 | Implemented |
SD0091 # 04 Y:1994 | 04 | 1994 | INSTALL SPECTRAL REFLECTORS / DELAMP | $1,418 | $1,660 | Implemented |
SD0091 # 05 Y:1994 | 05 | 1994 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $21,632 | $24,414 | Implemented |
SD0091 # 06 Y:1994 | 06 | 1994 | USE PHOTOCELL CONTROLS | $4,905 | $2,245 | Not Implemented |
SD0091 # 07 Y:1994 | 07 | 1994 | INSTALL TIMERS AND/OR THERMOSTATS | $3,165 | $300 | Implemented |
MS0005 # 01 Y:1994 | 01 | 1994 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $5,137 | $2,700 | Not Implemented |
MS0005 # 02 Y:1994 | 02 | 1994 | USE WATER ON AIR CONDITIONING EXCHANGER TO IMPROVE HEAT TRANSFER AND INCREASE AIR CONDITIONER EFFICIENCY | $1,737 | $8,100 | Not Implemented |
MS0005 # 03 Y:1994 | 03 | 1994 | UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING | $628 | $500 | Not Implemented |
MS0005 # 04 Y:1994 | 04 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,714 | $1,321 | Not Implemented |