Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,525
matching recommendationsSIC | 25 | Furniture And Fixtures |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0163 # 03 Y:1985 | 03 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,583 | $2,300 | Implemented |
UD0163 # 04 Y:1985 | 04 | 1985 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $22,293 | $19,340 | Not Implemented |
UD0163 # 05 Y:1985 | 05 | 1985 | RECOVER WASTE HEAT FROM EQUIPMENT | $16,003 | $2,000 | Implemented |
UD0163 # 06 Y:1985 | 06 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $17,374 | $7,500 | Implemented |
TS0012 # 01 Y:1985 | 01 | 1985 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $952 | $30 | Implemented |
TS0012 # 02 Y:1985 | 02 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $365 | $300 | Not Implemented |
TS0012 # 03 Y:1985 | 03 | 1985 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $13,907 | $0 | Implemented |
TS0012 # 04 Y:1985 | 04 | 1985 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $2,998 | $9,765 | Implemented |
TN0233 # 01 Y:1984 | 01 | 1984 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $4,090 | $3,430 | Not Implemented |
TN0233 # 02 Y:1984 | 02 | 1984 | INSTALL / REPAIR INSULATION ON STEAM LINES | $118 | $186 | Implemented |
TN0233 # 03 Y:1984 | 03 | 1984 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $40 | $117 | Implemented |
TN0233 # 04 Y:1984 | 04 | 1984 | BURN WOOD BY-PRODUCTS FOR HEAT | $731 | $5,000 | Not Implemented |
TN0233 # 05 Y:1984 | 05 | 1984 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $636 | $95 | Implemented |
TN0233 # 06 Y:1984 | 06 | 1984 | INSTALL SET-BACK TIMERS | $398 | $0 | Implemented |
TN0222 # 01 Y:1984 | 01 | 1984 | BURN FOSSIL FUEL TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR AND USE STEAM EXHAUST FOR HEAT | $171,149 | $240,000 | Not Implemented |
TN0222 # 02 Y:1984 | 02 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $8,367 | $0 | Implemented |
TN0222 # 03 Y:1984 | 03 | 1984 | INSULATE BARE EQUIPMENT | $1,224 | $1,817 | Implemented |
TN0222 # 04 Y:1984 | 04 | 1984 | USE MINIMUM STEAM OPERATING PRESSURE | $687 | $0 | Not Implemented |
TN0222 # 05 Y:1984 | 05 | 1984 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $14,520 | $3,000 | Implemented |
TN0222 # 06 Y:1984 | 06 | 1984 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $953 | $270 | Implemented |
LT0006 # 01 Y:1984 | 01 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $610 | $300 | Implemented |
LT0006 # 02 Y:1984 | 02 | 1984 | BURN WOOD BY-PRODUCTS FOR HEAT | $38,459 | $225,000 | Implemented |
LT0006 # 03 Y:1984 | 03 | 1984 | COVER OPEN TANKS | $1,646 | $506 | Not Implemented |
LT0006 # 04 Y:1984 | 04 | 1984 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $640 | $105 | Implemented |
LT0006 # 05 Y:1984 | 05 | 1984 | INSULATE BARE EQUIPMENT | $740 | $1,600 | Not Implemented |