Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Oklahoma State University
Assessment Year 1986
Principal Product HIGH QUALITY FURNITURE
NAICS n/a
SIC 2511 - Wood Household Furniture
Sales $1,000,000-$5,000,000
# of Employees 50
Plant Area (Sq.Ft.) 0
Annual Production 0 Units
Production Hrs. Annual 2,340
Location (State) OK
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $23,910 349,062 kWh $0.07
Natural Gas $16,873 3,889 MMBtu $4.34
TOTAL ENERGY COSTS $40,783
RECOMMENDED SAVINGS* $5,459 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $958
#|Description Savings
Cost
Status Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes
$ kWh $ MMBtu $ $
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$418
Cost:
$41
$418 6,741 - - - - $418
6,741
kWh
-
-
MMBtu
-
-
$
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$227
Cost:
$363
$227 3,517 - - - - $227
3,517
kWh
-
-
MMBtu
-
-
$
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$273
Cost:
$60
$333 9,086 - - $(-60) - $333
9,086
kWh
-
-
MMBtu
$(-60)
-
$
04: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$40
Cost:
$55
$40 586 - - - - $40
586
kWh
-
-
MMBtu
-
-
$
05: 2.7231 USE RADIANT HEATER FOR SPOT HEATING Savings:
$4,501
Cost:
$16,900
- - $4,501 1,037 - - -
-
kWh
$4,501
1,037
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$5,459
Cost:
$17,419
$1,018 19,930 $4,501 1,037 $(-60) - $1,018
19,930
kWh
$4,501
1,037
MMBtu
$(-60)
-
$
TOTAL IMPLEMENTED Savings:
$958
Cost:
$519
$1,018 19,930 - - $(-60) - $1,018
19,930
kWh
-
-
MMBtu
$(-60)
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes