Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,525
matching recommendationsSIC | 25 | Furniture And Fixtures |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BS0038 # 04 Y:2014 | 04 | 2014 | INSTALL OCCUPANCY SENSORS | $1,312 | $313 | Not Implemented |
BS0038 # 05 Y:2014 | 05 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $60 | $258 | Not Implemented |
BS0038 # 06 Y:2014 | 06 | 2014 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $387 | $600 | Not Implemented |
BS0038 # 07 Y:2014 | 07 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,579 | $26,537 | Not Implemented |
IA0517 # 01 Y:2014 | 01 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,210 | $775 | Implemented |
IA0517 # 02 Y:2014 | 02 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,892 | $693 | Implemented |
IA0517 # 03 Y:2014 | 03 | 2014 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $1,269 | $4,025 | Not Implemented |
IA0517 # 04 Y:2014 | 04 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $889 | $35 | Not Implemented |
IA0517 # 05 Y:2014 | 05 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $609 | $3,115 | Not Implemented |
IA0517 # 06 Y:2014 | 06 | 2014 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $19,006 | $15,000 | Not Implemented |
SD0483 # 01 Y:2014 | 01 | 2014 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $18,026 | $61,400 | Implemented |
SD0483 # 02 Y:2014 | 02 | 2014 | INSULATE BARE EQUIPMENT | $7,108 | $21,254 | Not Implemented |
SD0483 # 03 Y:2014 | 03 | 2014 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $5,486 | $2,845 | Implemented |
SD0483 # 04 Y:2014 | 04 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,633 | $2,600 | Implemented |
SD0483 # 05 Y:2014 | 05 | 2014 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,563 | $3,243 | Implemented |
SD0483 # 06 Y:2014 | 06 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,147 | $500 | Implemented |
SD0483 # 07 Y:2014 | 07 | 2014 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $783 | $500 | Implemented |
NC0509 # 01 Y:2014 | 01 | 2014 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $6,707 | $1,000 | Implemented |
NC0509 # 02 Y:2014 | 02 | 2014 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,152 | $157 | Implemented |
NC0509 # 03 Y:2014 | 03 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,187 | $1,625 | Implemented |
NC0509 # 04 Y:2014 | 04 | 2014 | INSTALL OCCUPANCY SENSORS | $411 | $697 | Implemented |
NC0509 # 05 Y:2014 | 05 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $798 | $3,231 | Not Implemented |
NC0509 # 06 Y:2014 | 06 | 2014 | INSULATE FEEDWATER TANK | $198 | $75 | Implemented |
NC0509 # 07 Y:2014 | 07 | 2014 | INSTALL / REPAIR INSULATION ON STEAM LINES | $792 | $787 | Not Implemented |
NC0509 # 08 Y:2014 | 08 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $585 | $50 | Not Implemented |