Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
468
matching recommendationsSIC | 25 | Furniture And Fixtures |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0509 # 10 Y:2014 | 10 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $270 | $100 | Implemented |
NC0509 # 11 Y:2014 | 11 | 2014 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $85 | $105 | Implemented |
NC0500 # 01 Y:2013 | 01 | 2013 | USE FOSSIL FUEL POWERED GENERATOR DURING PEAK DEMAND PERIODS | $59,689 | $250,000 | Not Implemented |
NC0500 # 02 Y:2013 | 02 | 2013 | MAKE A NEW BY-PRODUCT | $86,815 | $250,000 | Implemented |
NC0500 # 03 Y:2013 | 03 | 2013 | AIR CONDITION ONLY SPACE NECESSARY | $4,146 | $200 | Implemented |
NC0500 # 04 Y:2013 | 04 | 2013 | REDUCE FLUID FLOW RATES | $34,287 | $18,000 | Implemented |
NC0500 # 05 Y:2013 | 05 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,558 | $100 | Implemented |
NC0500 # 06 Y:2013 | 06 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,293 | $125 | Implemented |
NC0500 # 07 Y:2013 | 07 | 2013 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $577 | $875 | Implemented |
NC0500 # 08 Y:2013 | 08 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $9,389 | $7,000 | Implemented |
NC0500 # 09 Y:2013 | 09 | 2013 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $286 | $750 | Not Implemented |
NC0500 # 10 Y:2013 | 10 | 2013 | METER WASTE WATER | $4,155 | $4,200 | Implemented |
NC0500 # 11 Y:2013 | 11 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $456 | $2,704 | Not Implemented |
NC0500 # 12 Y:2013 | 12 | 2013 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,622 | $775 | Implemented |
NC0500 # 13 Y:2013 | 13 | 2013 | INSTALL OCCUPANCY SENSORS | $596 | $1,565 | Not Implemented |
NC0496 # 10 Y:2013 | 10 | 2013 | CONDENSE OPERATION INTO ONE BUILDING | $37,518 | $5,000 | Implemented |
NC0496 # 09 Y:2013 | 09 | 2013 | OPTIMIZE LOT SIZES TO REDUCE INVENTORY CARRYING COSTS | $65,547 | $10,000 | Implemented |
NC0496 # 08 Y:2013 | 08 | 2013 | USE PHOTOCELL CONTROLS | $575 | $200 | Implemented |
NC0496 # 07 Y:2013 | 07 | 2013 | INSTALL OCCUPANCY SENSORS | $1,315 | $3,203 | Implemented |
NC0496 # 06 Y:2013 | 06 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,131 | $100 | Implemented |
NC0496 # 05 Y:2013 | 05 | 2013 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $1,899 | $7,281 | Not Implemented |
NC0496 # 04 Y:2013 | 04 | 2013 | REDUCE FLUID FLOW RATES | $698 | $3,000 | Implemented |
NC0496 # 03 Y:2013 | 03 | 2013 | CLOSE OFF UNNEEDED STEAM LINES | $638 | $0 | Implemented |
NC0496 # 02 Y:2013 | 02 | 2013 | USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR | $21,698 | $75,000 | Not Implemented |
NC0496 # 01 Y:2013 | 01 | 2013 | REDUCE EXCESSIVE BOILER BLOWDOWN | $1,814 | $0 | Implemented |