Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
468
matching recommendationsSIC | 25 | Furniture And Fixtures |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0466 # 12 Y:2012 | 12 | 2012 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,066 | $3,000 | Implemented |
NC0466 # 13 Y:2012 | 13 | 2012 | INCREASE AMOUNT OF CONDENSATE RETURNED | $854 | $2,000 | Implemented |
NC0466 # 14 Y:2012 | 14 | 2012 | INCREASE AMOUNT OF CONDENSATE RETURNED | $425 | $650 | Implemented |
NC0466 # 15 Y:2012 | 15 | 2012 | INSULATE FEEDWATER TANK | $482 | $1,542 | Not Implemented |
NC0441 # 01 Y:2012 | 01 | 2012 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $8,551 | $44,599 | Implemented |
NC0441 # 02 Y:2012 | 02 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $875 | $0 | Implemented |
NC0441 # 03 Y:2012 | 03 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $161 | $100 | Implemented |
NC0441 # 04 Y:2012 | 04 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $782 | $300 | Not Implemented |
NC0441 # 05 Y:2012 | 05 | 2012 | TURN OFF EQUIPMENT WHEN NOT IN USE | $9,319 | $1,000 | Not Implemented |
NC0441 # 06 Y:2012 | 06 | 2012 | TURN OFF EQUIPMENT WHEN NOT IN USE | $4,151 | $1,000 | Not Implemented |
NC0441 # 07 Y:2012 | 07 | 2012 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $350 | $800 | Implemented |
NC0441 # 08 Y:2012 | 08 | 2012 | INCREASE AMOUNT OF CONDENSATE RETURNED | $462 | $600 | Implemented |
NC0441 # 09 Y:2012 | 09 | 2012 | MINIMIZE BOILER BLOWDOWN WITH BETTER FEEDWATER TREATMENT | $1,800 | $1,000 | Not Implemented |
NC0441 # 10 Y:2012 | 10 | 2012 | REPAIR OR REPLACE STEAM TRAPS | $1,119 | $1,000 | Implemented |
NC0441 # 11 Y:2012 | 11 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,596 | $4,760 | Implemented |
NC0441 # 12 Y:2012 | 12 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $551 | $7,310 | Implemented |
NC0441 # 13 Y:2012 | 13 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $659 | $5,880 | Implemented |
NC0441 # 14 Y:2012 | 14 | 2012 | DEVELOP A REPAIR/REPLACE POLICY | $500 | $1,980 | Implemented |
NC0441 # 15 Y:2012 | 15 | 2012 | USE HEAT PUMP FOR SPACE CONDITIONING | $1,795 | $10,400 | Not Implemented |
NC0419 # 01 Y:2011 | 01 | 2011 | TURN OFF EQUIPMENT WHEN NOT IN USE | $967 | $25 | Implemented |
NC0419 # 02 Y:2011 | 02 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,212 | $2,582 | Not Implemented |
NC0419 # 03 Y:2011 | 03 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $174 | $50 | Implemented |
NC0419 # 04 Y:2011 | 04 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $363 | $100 | Implemented |
NC0419 # 05 Y:2011 | 05 | 2011 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $873 | $50 | Implemented |
NC0419 # 06 Y:2011 | 06 | 2011 | INSTALL OCCUPANCY SENSORS | $139 | $517 | Implemented |