IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

81

matching recommendations
Reset
SIC 251 Household Furniture
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TN0530 # 06 Y:1994 06 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,330 $1,670 Not Implemented
TN0530 # 07 Y:1994 07 1994 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $1,436 $1,500 Not Implemented
TN0530 # 08 Y:1994 08 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $703 $858 Not Implemented
TN0530 # 09 Y:1994 09 1994 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $586 $1,505 Not Implemented
TN0530 # 10 Y:1994 10 1994 MAKE A NEW BY-PRODUCT $100,000 $988,447 Implemented
TN0530 # 11 Y:1994 11 1994 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS $341,760 $52,450 Not Implemented
TN0530 # 12 Y:1994 12 1994 $13,320 $2,664 Not Implemented
OK0435 # 04 Y:1994 04 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,461 $3,216 Not Implemented
OK0435 # 01 Y:1994 01 1994 REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT $2,102 $7,500 Not Implemented
OK0435 # 02 Y:1994 02 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $374 $739 Not Implemented
OK0435 # 03 Y:1994 03 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $734 $0 Not Implemented
OK0435 # 06 Y:1994 06 1994 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $2,031 $0 Not Implemented
OK0435 # 07 Y:1994 07 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $555 $0 Not Implemented
OK0435 # 08 Y:1994 08 1994 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $671 $450 Not Implemented
OK0435 # 09 Y:1994 09 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $658 $1,539 Not Implemented
OK0435 # 05 Y:1994 05 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,330 $6,068 Not Implemented
NC0016 # 03 Y:1994 03 1994 USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR $5,634 $38,500 Not Implemented
NC0016 # 01 Y:1994 01 1994 INSTALL TURBULATORS $68,797 $3,000 Not Implemented
NC0016 # 02 Y:1994 02 1994 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $11,812 $15,750 Not Implemented
NC0016 # 04 Y:1994 04 1994 RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING $42,728 $34,300 Not Implemented
NC0016 # 05 Y:1994 05 1994 USE OPTIMUM THICKNESS INSULATION $61,266 $133,293 Not Implemented
NC0016 # 06 Y:1994 06 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,603 $1,000 Not Implemented
NC0016 # 07 Y:1994 07 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,831 $960 Implemented
NC0016 # 08 Y:1994 08 1994 BURN A LESS EXPENSIVE GRADE OF FUEL $40,563 $118,090 Not Implemented
ME0118 # 07 Y:1994 07 1994 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $549 $1,050 Not Implemented