Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
162
matching recommendationsSIC | 2515 | Mattresses And Bedsprings |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MS0320 # 01 Y:2007 | 01 | 2007 | BURN WASTE TO PRODUCE STEAM TO DRIVE A STEAM TURBINE GENERATOR SET AND USE STEAM EXHAUST FOR HEAT | $49,454 | $130,000 | Not Implemented |
MS0320 # 04 Y:2007 | 04 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,936 | $10,579 | Implemented |
MS0320 # 02 Y:2007 | 02 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,042 | $8,052 | Not Implemented |
MS0320 # 03 Y:2007 | 03 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,124 | $356 | Implemented |
MS0320 # 06 Y:2007 | 06 | 2007 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $246 | $375 | Implemented |
MS0320 # 05 Y:2007 | 05 | 2007 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $340 | $635 | Implemented |
MI0149 # 05 Y:2007 | 05 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,014 | $30 | Not Implemented |
MI0149 # 03 Y:2007 | 03 | 2007 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $5,814 | $120 | Implemented |
MI0149 # 01 Y:2007 | 01 | 2007 | USE PHOTOCELL CONTROLS | $13,292 | $3,157 | Not Implemented |
MI0149 # 04 Y:2007 | 04 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,030 | $1,074 | Implemented |
MI0149 # 02 Y:2007 | 02 | 2007 | INSTALL SKYLIGHTS | $6,818 | $21,792 | Not Implemented |
OK0747 # 01 Y:2007 | 01 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $7,165 | $4,559 | Implemented |
OK0747 # 07 Y:2007 | 07 | 2007 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $2,068 | $200 | Not Implemented |
OK0747 # 05 Y:2007 | 05 | 2007 | USE SOLAR HEAT FOR HEAT | $14,978 | $138,320 | Not Implemented |
OK0747 # 06 Y:2007 | 06 | 2007 | INSTALL SKYLIGHTS | $22,903 | $139,000 | Not Implemented |
OK0747 # 03 Y:2007 | 03 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,756 | $0 | Not Implemented |
OK0747 # 04 Y:2007 | 04 | 2007 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $7,099 | $0 | Not Implemented |
OK0747 # 02 Y:2007 | 02 | 2007 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $991 | $326 | Not Implemented |
AS0386 # 07 Y:2004 | 07 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,758 | $35,730 | Implemented |
AS0386 # 06 Y:2004 | 06 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $437 | $850 | Not Implemented |
AS0386 # 05 Y:2004 | 05 | 2004 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $7,680 | $2,000 | Not Implemented |
AS0386 # 04 Y:2004 | 04 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $205 | $254 | Not Implemented |
AS0386 # 03 Y:2004 | 03 | 2004 | INSTALL OCCUPANCY SENSORS | $639 | $1,350 | Implemented |
AS0386 # 02 Y:2004 | 02 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,011 | $15 | Implemented |
AS0386 # 01 Y:2004 | 01 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,031 | $120 | Implemented |