Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
24
matching recommendationsSIC | 2521 | Wood Office Furniture |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MS0170 # 03 Y:2000 | 03 | 2000 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $29,773 | $41,847 | Implemented |
MS0170 # 02 Y:2000 | 02 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,522 | $296 | Implemented |
MS0170 # 01 Y:2000 | 01 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $400 | $504 | Implemented |
MS0166 # 07 Y:2000 | 07 | 2000 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $29,386 | $2,399 | Not Implemented |
MS0166 # 06 Y:2000 | 06 | 2000 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $11,439 | $7,938 | Not Implemented |
MS0166 # 05 Y:2000 | 05 | 2000 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,157 | $376 | Not Implemented |
MS0166 # 04 Y:2000 | 04 | 2000 | INSTALL TIMERS AND/OR THERMOSTATS | $311 | $472 | Not Implemented |
MS0166 # 03 Y:2000 | 03 | 2000 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,903 | $3,464 | Not Implemented |
MS0166 # 02 Y:2000 | 02 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $551 | $222 | Not Implemented |
MS0166 # 01 Y:2000 | 01 | 2000 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $190 | $70 | Implemented |
AR0186 # 02 Y:2000 | 02 | 2000 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $8,772 | $800 | Not Implemented |
AR0186 # 05 Y:2000 | 05 | 2000 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS | $26,957 | $400 | Not Implemented |
AR0186 # 04 Y:2000 | 04 | 2000 | RECYCLE NONFERROUS DUST | $28,860 | $0 | Not Implemented |
AR0186 # 03 Y:2000 | 03 | 2000 | OPTIMIZE PLANT POWER FACTOR | $17,663 | $54,855 | Implemented |
AR0186 # 01 Y:2000 | 01 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,117 | $23,976 | Implemented |
MS0160 # 07 Y:2000 | 07 | 2000 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,708 | $2,195 | Not Implemented |
MS0160 # 08 Y:2000 | 08 | 2000 | COMBINE UTILITY METERS | $3,023 | $1,000 | Not Implemented |
MS0160 # 09 Y:2000 | 09 | 2000 | BURN WASTE OIL FOR HEAT | $1,949 | $2,067 | Not Implemented |
MS0160 # 06 Y:2000 | 06 | 2000 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $915 | $2,700 | Not Implemented |
MS0160 # 05 Y:2000 | 05 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $593 | $3,002 | Not Implemented |
MS0160 # 04 Y:2000 | 04 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,075 | $9,610 | Not Implemented |
MS0160 # 03 Y:2000 | 03 | 2000 | INSTALL TIMERS AND/OR THERMOSTATS | $469 | $472 | Not Implemented |
MS0160 # 02 Y:2000 | 02 | 2000 | USE SYNTHETIC LUBRICANT | $1,840 | $1,210 | Implemented |
MS0160 # 01 Y:2000 | 01 | 2000 | BURN A LESS EXPENSIVE GRADE OF FUEL | $2,113 | $710 | Not Implemented |