Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

55

matching recommendations
Reset
SIC 254 Partitions And Fixtures
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MZ0164 # 02 Y:2014 02 2014 INSULATE BARE EQUIPMENT $1,744 $1,500 Not Implemented
MZ0164 # 03 Y:2014 03 2014 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $71,454 $0 Implemented
MZ0164 # 04 Y:2014 04 2014 UPGRADE CONTROLS ON COMPRESSORS $24,203 $100,000 Implemented
MZ0164 # 05 Y:2014 05 2014 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $13,593 $6,500 Implemented
MZ0164 # 06 Y:2014 06 2014 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,200 $1,430 Implemented
MZ0164 # 07 Y:2014 07 2014 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $47,302 $25,000 Implemented
KU0551 # 05 Y:2000 05 2000 RECOVER AND REUSE WASTE MATERIAL $26,760 $37,200 Not Implemented
KU0551 # 04 Y:2000 04 2000 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $827 $700 Not Implemented
KU0551 # 03 Y:2000 03 2000 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,370 $890 Not Implemented
KU0551 # 02 Y:2000 02 2000 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,010 $60 Not Implemented
KU0551 # 01 Y:2000 01 2000 PREHEAT COMBUSTION AIR WITH WASTE HEAT $8,821 $18,000 Not Implemented
KU0248 # 02 Y:1988 02 1988 RECOVER AND REUSE COOLING WATER $19,728 $9,000 Implemented
KU0248 # 13 Y:1988 13 1988 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $176 $0 Implemented
KU0248 # 12 Y:1988 12 1988 IMPROVE LUBRICATION PRACTICES $275 $0 Implemented
KU0248 # 11 Y:1988 11 1988 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $451 $450 Not Implemented
KU0248 # 10 Y:1988 10 1988 INSTALL / REPAIR INSULATION ON STEAM LINES $545 $850 Implemented
KU0248 # 09 Y:1988 09 1988 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $608 $40 Implemented
KU0248 # 08 Y:1988 08 1988 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $988 $14 Implemented
KU0248 # 07 Y:1988 07 1988 USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD $1,435 $267 Not Implemented
KU0248 # 06 Y:1988 06 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,843 $2,961 Implemented
KU0248 # 05 Y:1988 05 1988 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,471 $150 Implemented
KU0248 # 04 Y:1988 04 1988 COVER OPEN TANKS $2,897 $600 Implemented
KU0248 # 03 Y:1988 03 1988 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $4,505 $0 Implemented
KU0248 # 01 Y:1988 01 1988 USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD $20,271 $2,500 Implemented
KU0197 # 05 Y:1986 05 1986 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $170 $0 Implemented