Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
18
matching recommendationsSIC | 2542 | Partitions And Fixtures, Except Wood |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0160 # 02 Y:1996 | 02 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $269 | $312 | Implemented |
IA0160 # 10 Y:1996 | 10 | 1996 | MINIMIZE WATER USAGE | $790 | $750 | Implemented |
IA0160 # 09 Y:1996 | 09 | 1996 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $1,059 | $1,200 | Implemented |
IA0160 # 08 Y:1996 | 08 | 1996 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $2,597 | $500 | Implemented |
IA0160 # 07 Y:1996 | 07 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $436 | $300 | Implemented |
IA0160 # 06 Y:1996 | 06 | 1996 | TURN OFF EQUIPMENT WHEN NOT IN USE | $74 | $0 | Implemented |
IA0160 # 05 Y:1996 | 05 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,176 | $132 | Implemented |
IA0160 # 04 Y:1996 | 04 | 1996 | INSTALL DIRECT ACTING UNITS IN PLACE OF COMPRESSED AIR PRESSURE SYSTEM IN SAFETY SYSTEM | $3,423 | $805 | Implemented |
IA0160 # 03 Y:1996 | 03 | 1996 | INSTALL OCCUPANCY SENSORS | $292 | $616 | Not Implemented |
IA0160 # 01 Y:1996 | 01 | 1996 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $10,923 | $4,200 | Not Implemented |
MS0048 # 01 Y:1996 | 01 | 1996 | OPTIMIZE PLANT POWER FACTOR | $4,277 | $3,000 | Implemented |
MS0048 # 02 Y:1996 | 02 | 1996 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $16,746 | $10,140 | Not Implemented |
MS0048 # 03 Y:1996 | 03 | 1996 | COVER OPEN TANKS | $127 | $304 | Not Implemented |
MS0048 # 04 Y:1996 | 04 | 1996 | USE SYNTHETIC LUBRICANT | $2,734 | $400 | Implemented |
MS0048 # 05 Y:1996 | 05 | 1996 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $2,749 | $1,440 | Not Implemented |
MS0048 # 06 Y:1996 | 06 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,099 | $300 | Not Implemented |
MS0048 # 07 Y:1996 | 07 | 1996 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $11,000 | $6,500 | Not Implemented |
MS0048 # 08 Y:1996 | 08 | 1996 | DISTILL CONTAMINATED SOLVENTS FOR REUSE | $14,802 | $0 | Not Implemented |