Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
348
matching recommendationsSIC | 26 | Paper And Allied Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0351 # 03 Y:1991 | 03 | 1991 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $4,426 | $7,600 | Not Implemented |
UD0351 # 04 Y:1991 | 04 | 1991 | INSTALL SET-BACK TIMERS | $5,440 | $0 | Not Implemented |
UD0321 # 01 Y:1990 | 01 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,217 | $37,000 | Implemented |
UD0321 # 02 Y:1990 | 02 | 1990 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,310 | $7,500 | Implemented |
UD0321 # 03 Y:1990 | 03 | 1990 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,760 | $1,100 | Implemented |
UD0321 # 04 Y:1990 | 04 | 1990 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $10,068 | $14,000 | Not Implemented |
UD0305 # 01 Y:1990 | 01 | 1990 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $1,230 | $0 | Not Implemented |
UD0305 # 02 Y:1990 | 02 | 1990 | INSTALL STORM WINDOWS AND DOORS | $8,782 | $8,000 | Not Implemented |
UD0305 # 03 Y:1990 | 03 | 1990 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $1,494 | $1,500 | Not Implemented |
UD0305 # 04 Y:1990 | 04 | 1990 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,214 | $1,500 | Not Implemented |
UD0305 # 05 Y:1990 | 05 | 1990 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $874 | $0 | Not Implemented |
UD0266 # 01 Y:1988 | 01 | 1988 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $7,611 | $600 | Implemented |
UD0266 # 02 Y:1988 | 02 | 1988 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $462 | $0 | Implemented |
UD0266 # 03 Y:1988 | 03 | 1988 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $10,213 | $7,000 | Not Implemented |
UD0266 # 04 Y:1988 | 04 | 1988 | REPAIR AND ELIMINATE STEAM LEAKS | $21,603 | $5,000 | Implemented |
UD0266 # 05 Y:1988 | 05 | 1988 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $23,169 | $20,000 | Implemented |
UD0266 # 06 Y:1988 | 06 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,639 | $11,475 | Implemented |
UD0266 # 07 Y:1988 | 07 | 1988 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $9,266 | $30,000 | Implemented |
UD0266 # 08 Y:1988 | 08 | 1988 | BURN FOSSIL FUEL TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR AND USE STEAM EXHAUST FOR HEAT | $155,320 | $875,000 | Not Implemented |
UD0253 # 01 Y:1988 | 01 | 1988 | REDUCE VENTILATION AIR | $2,007 | $900 | Implemented |
UD0253 # 02 Y:1988 | 02 | 1988 | REPLACE WATER COOLING ON PROCESSES WITH AIR COOLING | $15,536 | $20,000 | Implemented |
UD0253 # 03 Y:1988 | 03 | 1988 | INSULATE BARE EQUIPMENT | $875 | $805 | Implemented |
UD0253 # 04 Y:1988 | 04 | 1988 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $4,830 | $8,000 | Implemented |
UD0253 # 05 Y:1988 | 05 | 1988 | INSTALL STORM WINDOWS AND DOORS | $804 | $700 | Implemented |
UD0248 # 01 Y:1988 | 01 | 1988 | COMBINE UTILITY METERS | $1,427 | $0 | Implemented |